background image

 

5

Unpacking 

Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are 
present and have been received in good condition.  If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling, notify the shipper immediately.  Retain 
carton and all packing material for inspection.  In the event that the merchandise is to be 
returned, the original carton and packing must be used.  The customer will be billed for a new 
carton and packing if merchandise is received without the original carton and packing. 
 
 

Claims 

Physical damage must be reported to the Freight Carrier or Shipping Company upon 
receipt of merchandise.  Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company.  It is the customer’s obligation in the event that 
merchandise is received damaged, to notify the Freight Carrier or Shipping Company 
immediately.  All other claims not related to damage incurred during shipping must be 
made to the Dealer or Distributor within 7 days of receiving merchandise.  

 
 

Returns 

Returned merchandise must be in the original packing with a Return Merchandise 
Authorization number (RMA) clearly listed on the shipping label.    Items sent by Freight 
Collect or without a RMA number will be refused.   Call your sales person and request a 
RMA prior to shipping.  Be prepared to provide the model number, serial number and 
description of the nature of the return.  Shipping damage resulting from inadequate 
packaging is the customer’s responsibility.  Customer will be charged additional shipping 
charges to return products received in non original packing and or cartons. 

 
 

Power 

 

Do not apply power to the fixture until power source is verified. 

 

For protection against electric shock, fixture must be connected to suitable earth ground. 
Make sure fixture is disconnected from power mains before any service. 

 
This fixture automatically adjusts to mains voltage and frequency 100-230vac 50/60Hz.  The 
listed power rating is its average wattage under normal conditions. All fixtures must be powered 
directly from a switched circuit.  This fixture cannot be run on a rheostat or dimmer circuit even 
if used solely for a 0% to 100% switching.  Before applying power to a fixture, check that the 
fixture’s input voltage matches the power source voltage.  Consult a qualified electrician if there 
are any concerns about proper connection to power. 
 
 

Mounting 

Always consult a qualified professional when rigging.  Consider access for routine maintenance 
when selecting a mounting position. This fixture may be mounted in any position provided there 
is adequate room for movement and ventilation.  Mount the fixture securely using a mounting 
clamp and a safety cable.  Do not mount where the fixture will be exposed to rain, high 
humidity, extreme temperature changes or restricted ventilation.  Do not obstruct any vents. 

Содержание DL-PANEL1-192U

Страница 1: ...Information specifically for DL PANEL1 192U V1 This manual contains important information Please read before operating fixture...

Страница 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Страница 3: ...ration Modes 6 Stand Alone Mode 6 DMX Controlling Mode 7 DMX 512 Control 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 8 DMX Channel Assignment 9 CH 1 Dimmer 9 CH 2...

Страница 4: ...7 x 3 62 Weight 4 5 lbs 2 0 kgs Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Vol...

Страница 5: ...pping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer wi...

Страница 6: ...ode is selectable by setting the dip switch combination from the information below The DMX mode requires data interconnect cables and a controller to be used The stand alone mode does not require any...

Страница 7: ...more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 2 channels of DMX if set to a Start Address of 7 it would use da...

Страница 8: ...ssible from the selected start address which does not cause a negative number Continue this process until zero is reached always subtracting the largest possible value that does not cause a negative E...

Страница 9: ...3 2 5 and occupy channels 5 thru 6 The last fixture is addressed 5 2 7 and will occupy channels 7 thru 8 Thus 4 fixtures using 2 channels each have Start Addresses of 1 3 5 and 7 and the next free cha...

Страница 10: ...optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory It...

Страница 11: ...s are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as...

Отзывы: