background image

 

11

Troubleshooting 

Symptom 

Possible Cause / Solution 

Check for power on mains 

No Power 

Check main fuse and fuse holder 

Check data cables: connection and proper wiring 

Check DIP Switch settings (#10 set to on) 

Erratic / No response to DMX 

Check Start Address 

Check Start Address 

Check for overlapping addresses 

Check DIP Switch settings 

Incorrectly responds to DMX 
(Diagnostic technique for DMX issues: Set 
suspect fixture’s Start Address the same as a 
correctly functioning fixture. If both units then 
function correctly, issue is programming) 

Check Data cables (faults and proper wiring) 

 
 

DMX-512 Background 

DMX-512 is a digital data transmission standard developed by the United States Institute for Theater Technology 
(USITT).  It is designed to enable control of lighting equipment.  DMX deals solely with the formatting of data for 
transmission and does not dictate how the data is created or used. 
 
Under DMX, signals are transmitted in much the same way a computer modem transmits data.  The Data, divided 
into channels, is "Framed" using a start bit, high (1), eight data bits and finally, two stop bits, both high (1). DMX 
uses no parity to check the integrity of the signal.  Instead, DMX relies on the ultra low probability of an error 
occurring in the same place when the data is resent.  The rate at which data is sent is fixed at 250k bps, almost four 
and a half times faster that a 56k modem.   This speed allows all data on a DMX chain to be updated more than 44 
times every second. 
 
The transmitted data follows a specific format. DMX allows for 512 channels each with eight data bits, giving each 
channel the possibility of 256 values.  When a data "Packet" is sent, all channels are transmitted one after another.  
Even if the data on a specific channel has not been changed, it must be sent.  In a packet, a "start code" of all zeros 
is sent before the data to identify the signal as a Standard DMX transmission.  This start code is transparent to the 
user and is handled by the controller. 
 
The physical signals are transmitted using a twisted pair of wires and a common shield, a configuration called 
Balanced.  The controller and all receiving equipment are connected using a “Daisy Chain" connection.  The signal 
is jumped from the controller to a piece of DMX equipment.  From there, the signal is jumped to the next piece of 
equipment and so on until the last piece of equipment is connected.  No branches are allowed and the signal does 
not come back to the controller.  The final piece of equipment will have only one cable connection.  As a result, all 
equipment connected to the chain will see exactly the same signal whether it is first or last.  When connecting 
equipment, no particular attention needs to be paid to the order in which the equipment is connected.  Depending on 
the conditions and equipment, a line terminator may be required.  If there is any question, in most circumstances the 
addition of a terminator will not degrade the signal.  To make a terminator, attach a 120-ohm resistor between the 
Signal Data Negative and Signal Data Positive pins of a connector in the last piece of equipment in the chain. 
 
The DMX Standard uses 5 pin XLR connectors.  However, it is common to see 
fixtures with 3 pin XLR connectors as these types of balanced or “Lo-Z” cables 
are common in the audio industry.  In either case, pin numbers are the same and 
carry the same signals. 
 
 

 
 
10900 Palmbay Drive • Orlando, FL 32824 U.S.A. 
www.techni-lux.com 

Pin 

Connection 

Common (Shield) 

Data Negative (S- or Cold) 

Data Positive (S+ or Hot) 

n/c (not used) 

n/c (not used) 

Содержание DL-PANEL1-192U

Страница 1: ...Information specifically for DL PANEL1 192U V1 This manual contains important information Please read before operating fixture...

Страница 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Страница 3: ...ration Modes 6 Stand Alone Mode 6 DMX Controlling Mode 7 DMX 512 Control 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 8 DMX Channel Assignment 9 CH 1 Dimmer 9 CH 2...

Страница 4: ...7 x 3 62 Weight 4 5 lbs 2 0 kgs Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Vol...

Страница 5: ...pping Be prepared to provide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer wi...

Страница 6: ...ode is selectable by setting the dip switch combination from the information below The DMX mode requires data interconnect cables and a controller to be used The stand alone mode does not require any...

Страница 7: ...more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires 2 channels of DMX if set to a Start Address of 7 it would use da...

Страница 8: ...ssible from the selected start address which does not cause a negative number Continue this process until zero is reached always subtracting the largest possible value that does not cause a negative E...

Страница 9: ...3 2 5 and occupy channels 5 thru 6 The last fixture is addressed 5 2 7 and will occupy channels 7 thru 8 Thus 4 fixtures using 2 channels each have Start Addresses of 1 3 5 and 7 and the next free cha...

Страница 10: ...optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory It...

Страница 11: ...s are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as...

Отзывы: