5� Next set the pilot frequency levels by changing the
Pre-stage attenuator
values in the amplifier tab
schematic or parameter view table� Remember to click on
Send to amp
after changing the values
in the BLL application and check that the levels are correct on the RF spectrum analyzer�
6� Once the amplifier downstream/forward is commissioned, the software values can be recorded
on the PSU lid label using a permanent marker pen, they can also be saved electronically�
To save the amplifier settings electronically, enter the amplifier ID number into the
Amplifier name
field
as shown below�
Next, click on the
File tab
and then select on
Save backup file
� File name will be amplifier name
as in the screen shot above and the date at time of saving�