![technetix DBC-1200S Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/technetix/dbc-1200s/dbc-1200s_user-manual_1067187018.webp)
04/2019 - AE/V1.16
17
Technetix Group Limited
2.7 Downstream configuration
RF input/output splitters
Input bypass splitter selector
1� Referring to the network design documentation, configure the
Input bypass splitter
by installing
a 0 pad/jumper into the top three holes of the five holes (to pass all RF into the amplifier)�
Alternatively, install a relevant 2-way splitter or directional coupler�
Note: Left-hand two holes exposed with 0 pad/jumper in right-hand three holes.
2� When installing the directional coupler, ensure that it is inserted the correct way round so that the
through leg is passing RF into the correct path as required by the network design documentation�
Pin 5 is the tap leg�