![technetix AIMA3000.FT5X Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/technetix/aima3000-ft5x/aima3000-ft5x_product-user-manual_1067206040.webp)
AIMA3000.FT5X Product User Manual
Technetix Group Limited
•
technetix.com
May/2016 - Version 1.0
40
Module Alarm Indicator Definitions
Table 6-4 Module Alarm Indicator Definitions
Parameters (Common)
Description
Definitions
Related Indicators
Lighting Conditions
Power OFF
Power OFF
Power OFF
All
All OFF
Initiating AM
Power ON
During Module
Power ON
All
Green (2 times / sec)
No Alarm
Normal operation
Normal
All
Green
AM-Critical-ALM
Critical Alarm
STAT
Red
AM-Warning-ALM
Warning Alarm
STAT
Amber
Input AGC Mode
AGC / MGC Mode
Control
MODE
OFF(either port) Blinking,
ON (all ports)
Green always
RF-Critical-ALM
RF Input Power is too
high (HiHi) or too low
(LoLo).
STAT
LSR1/
LSR2/
LSR3/
LSR4
Red
RF-Warning-ALM
RF Input Power is higher
(Hi) or lower (Lo).
STA1T
LSR1/
LSR2/
LSR3/
LSR4
Amber
Laser-Critical-ALM
Laser Temperature is
too high (HiHi) or too low
(LoLo).
STAT
LSR1 /
LSR 2/
LSR3/
LSR4/
Red
Laser Bias Current is
too high (HiHi) or too low
(LoLo).
Laser Output Power is
too high (HiHi) or too low
(LoLo).
Laser Case Temperature
is too high (HiHi) or too
low (LoLo).
Laser-Warning-ALM
Laser Temperature is
higher (Hi) or lower (Lo).
STAT
LSR1/
LSR2/
LSR3/
LSR4
Amber
Laser Bias Current is
higher(Hi) or lower(Lo).
Laser Output Power is
higher(Hi) or lower(Lo).
Laser Case Temperature
is higher(Hi) or lower(Lo).
Содержание AIMA3000.FT5X