.1.  The  end  of  the  ribbon  should  lie  smoothly 
between the batteries and battery compartment 
cover. 
 
 
.2.  
Close  the  battery  compartment  by  first 
inserting  the  two  plastic  tabs  of  the  battery 
compartment  cover  into  the  slots  provided  for 
this  purpose  on  the  housing  of  the  endoscope 
camera. 
 

 

.3.  Then  press  it  downwards  until  it  audibly 
engages. 

 

Attaching & detaching the gooseneck 

 

 

To  ensure  the  tightness  of  the  screw  connection, 
remove  any  impurities  on  the  rubber  ring  (a)  and  on 
the screw thread (b) with a slightly damp cloth.  
 
To  maintain  the  flexibility  of  the  rubber  ring,  you 
should  lubricate  it  occasionally,  for  example,  with 
vaseline.  
 
The gooseneck can only be attached in one direction 
due  to  the  polarity  protection  feature.  Insert  the 
polarity  protection  for  this  purpose  into  the  slot 
provided (c). 

 

The gooseneck can then be screwed on.  
 
Turn the screw connection to the right until it is firmly 
secured. 

 

To  detach  the  gooseneck,  turn  the  screw  connection 
to the left until it is released.  
 
The  gooseneck  can  then  be  pulled  off  by  exerting  a 
little force. 

 
 

Содержание TX-116

Страница 1: ...Do the same with the original accessories for this product In case of warranty please contact the dealer or the store where you bought this product Warranty 2 years Introduction The endoscope camera T...

Страница 2: ...able camera illumination 8 stages with 4 white LED lights Easy operation via ON OFF button 3 buttons for 90 image rotation display brightness and endoscope light Lightweight handy design flexible and...

Страница 3: ...ice Remove the battery compartment cover by pressing the release mechanism and lifting the cover upwards The ribbon in the battery compartment is intended to facilitate the subsequent removal of the b...

Страница 4: ...move any impurities on the rubber ring a and on the screw thread b with a slightly damp cloth To maintain the flexibility of the rubber ring you should lubricate it occasionally for example with vasel...

Страница 5: ...htness adjustment display button 7 is pressed again the brightness adjustment is reset to the default value Changing the display The camera image can be rotated by 180 and mirrored vertically or horiz...

Страница 6: ...ack device in use for example TV Monitor displays a Battery charge level indicator permanent b LED lighting of the camera head display for 3 seconds when pressing the camera head illumination button 5...

Страница 7: ...e a different or better cable Safety instructions Neither the endoscope camera is for medical use nor for use on humans and animals There is a risk of a potentially fatal injury If there is smoke unus...

Страница 8: ...of water Consult a doctor immediately Operational safety The housing of the endoscope camera must not be opened because it does not contain any parts that require maintenance Ensure that the device i...

Страница 9: ...en a child swallowed a battery go to a doctors place or bring the child into a hospital promptly Look for the right polarity and of batteries Always change all batteries Never use old and new batterie...

Отзывы: