background image

19 

 

 

3.4.2 

Parameters Configuration 

3.4.2.1  Main Page 

 

PIC-3.4- 3 

Login the WEB network, you can notice that the WEB management network as a whole is 

divided into two functional areas: 

  Area to the left function menu is used to switch in a different configuration menu page.   

  Area to the right, displays the selected content of the configuration of the menu items.   

The WEB management page allows you to monitor and/or configure: Status, Inputs, Outputs, 

Decoder, CA, Local Setup, Import/Export, GPI Alarms Setting, User Management, License, 

Upgrade, Log and etc. 

Left menu section: 

This  area  shows  the  main  menu  items  of  the  machine,  you  can  click  the  item  you  want 

configure or monitor, then the detailed information will appear in the right area. 

 

Содержание TP160 IRD

Страница 1: ...TP160 IRD Professional HD Integrated Receiver Decoder User Manual V1 0RC...

Страница 2: ...to the deaths or serious injury There is medium or low potential danger If it cannot be avoided it will lead to medium or slight injury There are potential risks If ignore these texts it may cause da...

Страница 3: ...d product settings etc It is highly suggested users to go through this document before actually operating the device If you need help please contact us at Technalogix Ltd 4 8021 Edgar Industrial Place...

Страница 4: ...2 2 4 2 Connection Setup for ASI signal input 12 2 4 3 Connection Setup for IP signal input 12 3 Operation Guide 13 3 1 Operation Overview 13 3 2 Powering Up and Initialization 13 3 3 Front Panel Oper...

Страница 5: ...rds please do not open the receiver refer service to qualified personnel only Do not expose the device in the sunlight and keep it away from the heat source Do not block ventilation holes of the devic...

Страница 6: ...rned on when a channel is locked Otherwise there is no channel locked 3 Alarm status indicator This LED flickers when there is something abnormal For example the strength of the input signal is too we...

Страница 7: ...R AUDIO1 15 R AUDIO2 16 ASI OUT 2 17 ASI IN 2 18 RF OUT 19 RF IN 1 20 SDI OUT 21 SDI OUT 22 GENLOCK IN 23 CVBS OUT CC 24 AUDIO 1 4 Methods of Operation 1 4 1 Operation through WEB UI Operate the IRD...

Страница 8: ...as the followings Functions Description Related Items Parameters Setting Allows users to conduct operations of parameters configuration modification and setup Signal receive setup CI setup Decoder set...

Страница 9: ...ut optional Input Frequency 950 2150 MHz Frequency Range 48 862 MHz Constellation QPSK 8 PSK Modulation Mode 16 32 64 128 256 QAM DVB T2 Optional DVB T Optional Constellation 16 32 64 128 256 QAM Cons...

Страница 10: ...ytes per TS MPEG TS MPTS and SPTS Max bit rate 100 Mbps per TS Output processing Up to 4 Sockets max at 50 Mbps per socket The physical connector design is subject to change without advanced notice ei...

Страница 11: ...ser manual Has the knowledge of digital television system Has defined the sources racks allocation and set up plan system wiring Knows how to operate this unit and parameters configuration Go through...

Страница 12: ...electric shock and damage to the equipment before setting up the wiring connection please power off the equipment and all other connected external devices The equipment and external devices must be gr...

Страница 13: ...IRD with the monitor via HDMI SDI or CVBS ports 2 4 2 Connection Setup for ASI signal input Connect ASI signal to IRD ASI IN port with a BNC cable Connect the IRD Management port to a switch set up a...

Страница 14: ...ent through the rear power switch and the unit is powered up and starts the initialization The LCD screen is lighted up and display information as following The initialization takes about 20 seconds t...

Страница 15: ...y Tune TS Rate C N BER Input ASI Lock Status TS Rate Input IP Lock Status TS Rate Decoder TS Rate PCR PID Audio PID Video PID PMT PID Program No CI CI Slot 1 2 Output ASI TS Rate Output IP IP 1 2 3 4...

Страница 16: ...andard Scan TS IP Local Setting IP Address Subnet Mask Gateway Mac Address TSIP Channel 1 8 Source IP Address Source IP Port Protocol Outputs Setting Decoder Playing Program Video Video Standard Aspec...

Страница 17: ...ocal IP Address Local Subnet Mask Local Gateway Trap IP1 Adderss Trap IP2 Adderss MAC Address Version Alarms Setting LNB Connection Short GPI1 2 Alarm Mask Signal Unlock CAM Descrambling CAM Communica...

Страница 18: ...on to move the cursor in which change must be made o Press arrow UP button and arrow DOWN to input select an appropriate setting then press OK button to save 3 4 WEB UI Operation Accessing the equipme...

Страница 19: ...rowser will attempt to connect to the device If succeed a login page will appear see PIC 3 4 2 Note Through WEB browser you can manage several pieces of HD IRD at the same time as long as those equipm...

Страница 20: ...u page Area to the right displays the selected content of the configuration of the menu items The WEB management page allows you to monitor and or configure Status Inputs Outputs Decoder CA Local Setu...

Страница 21: ...ce for monitor and configuration of the machine where can show you the detailed information and you can operate it as follows 3 4 2 2 Status Page This page allows you to monitor the status of input an...

Страница 22: ...tatus Active Alarm Display the alarm information 3 4 2 3 Programs When you turn to the Programs interface where you are able to check and modify the parameter of programs output PIC 3 4 6 Source Selec...

Страница 23: ...ymbol rate you can get this parameter from the satellite program provider LNB Frequency this is the LNB s local oscillation LO frequency every LNB have one or two oscillation frequencies which can be...

Страница 24: ...e management server s IP should be in the same section Subnet Mask Network Mask setting for connecting to the server It should be the same as management server 255 255 255 0 Gateway Gateway setting fo...

Страница 25: ...s Source IP Address to input the IP address to include or exclude Source List the IP address added will be listed here 3 4 2 5 Outputs ASI Here you are able to set the Constant Rate of ASI signal Afte...

Страница 26: ...t must stay same with the value of the destination device Protocol You can choose UDP OR RTP for multicast unicast Constant Rate to set IP output bit rate 3 4 2 6 Decoder Playing This page shows Playi...

Страница 27: ...n o Video Output Resolution you can choose from the following video formats resolution for applying to the decoding output program Automatic 480i 576i 720p50 720p59 720p60 1080i50 1080i59 1080i60 1080...

Страница 28: ...EBU and DVB o Subtitle Language choose a language Teletext VBI In this section you can configure the information of Subtitle as follows PIC 3 4 17 o Enable to enable or disable the teletext function o...

Страница 29: ...M NTSC SECAM Audio Audio Volume It can be set from 63 to 0 Mixer 4 formats of audio supported including Stereo Left Right Mono and Dual Enhanced On Enhanced page you can set advanced program output pa...

Страница 30: ...nd Display Raster SDI In this section you can set Closed Caption and audio on SDI output SD EIA 708 B disable or enable SD EIA708 B output Line select specific line to be used for SD EIA 708 B SD VBI...

Страница 31: ...le CAM in a DTV receiver to adapt it to different kinds of cryptography o CAM Max Bitrate Set the max output bit rate of the CAM BISS BISS Basic Interoperable Scrambling System is a satellite signal s...

Страница 32: ...ling capability 3 4 2 8 System Local Setting PIC 3 4 22 In this page you can do factory set and reboot and able to configure the following parameters IP Address Local IP setting for connecting to the...

Страница 33: ...s of the device The MAC address is fixed and not editable Software Version Main Board Here shows the Software Version of Main Board Import Export This page allows you to import and export configuratio...

Страница 34: ...you should enter the old password firstly Change Username Here you can change the existed username to a new one Create a User The device allows you to add up to 10 new users to operate the device You...

Страница 35: ...or the WEB browser during the upgrade If succeed please restart the device and it will load the new version auto Log PIC 3 4 28 To get the Log for R D for analysis 3 4 2 9 Logout PIC 3 4 29 This inte...

Страница 36: ...UI to select correct input source in Inputs Source Select configuration page Refer to Figure 3 4 of this manual Signal Connection Make sure the signal is well connected to the right interfaces 1 Wheth...

Страница 37: ...Verification Result If the scrambled programs can be seen on the monitor after descrambling setting then it verifies the IRD descrambling function works well 3 5 3 Decoding Function Verification Prec...

Страница 38: ...cially Operation This section advises what need to be performed on the IRD before formally starts operation It includes but not limited to the following Clear test data Configure the equipment with wo...

Страница 39: ...g with long term stability It shall contain but not limited to the following items Check the strength and quality of all input signals Check if there is any alarm lights up on front panel LED indicato...

Страница 40: ...o the right TV mode Set TV in right mode e g Set TV to CVBS display mode for CVBS decoding input from IRD and HDMI mode for IRD HDMI input etc No or bad signal No cable connection or the program does...

Страница 41: ...ard to descramble the programs Cannot have access to the IRD through WEB UI IP setting Check whether the management PC IP and the IRD IP have been set to be in same section Network cable problem Make...

Страница 42: ...Terrestrial EBU European Broadcasting Union ETSI European Telecommunications Standards Institute FEC Forward Error Correction HD High Definition HDMI High Definition Multimedia Interface ISO Internati...