Techmed TMA-6000 Скачать руководство пользователя страница 5

Template version:1 

5/15

11. Information regarding potential electromagnetic or other interference between the blood 

pressure monitor and other devices together with advice regarding avoidance of such 
interference please see part ELECTROMAGNETIC COMPATIBILITY INFORMATION.

                                           

12. If Irregular Heartbeat (IHB) brought by common arrhythmias is detected in the procedure 

of blood pressure measurement, a signal of 

will be displayed. Under this condition, 

the Electronic Sphygmomanometers can keep function, but the results may not be 
accurate, it’s suggested that you consult with your physician for accurate assessment. 

      There are 2 conditions under which the signal of IHB will be displayed: 

1) The coefficient of variation (CV) of pulse period >25%. 
2) The difference of adjacent pulse period

0.14s, and the number of such pulse takes 

more than 53 percentage of the total number of pulse.   

13.  Please do not use the cuff other than supplied by the manufacturer, otherwise it may bring 

biocompatible hazard and might result in measurement error. 

14. 

 

The monitor might not meet its performance specifications or cause safety hazard if 

stored or used outside the specified temperature and humidity ranges in specifications. 

15. 

 

Please do not share the cuff with other infective person to avoid cross-infection. 

16. Medical AC adapter which output is DC 6.0V 600mA and complied with IEC 60601-1/EN 

60601-1/UL 60601-1 and IEC 60601-1-2/EN 60601-1-2/UL 60601-1-2 is suitable for this 
monitor. Please note that the monitor jack size: hole 

Φ

3.5mm, center pin 

Φ

1.0mm. Please 

pay attention to polarity.   

17. This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 
SETUP AND OPERATING PROCEDURES 

 

1. BATTERY 

LOADING  

 

a.  Open battery cover at the back of the monitor. 
b.  Load four “AA” size batteries. Please pay attention to polarity. 
c.  Close the battery cover. 

When LCD shows battery symbol

, replace all batteries with new ones.       

Содержание TMA-6000

Страница 1: ...TIONS 3 NOTICE 4 SETUP AND OPERATING PROCEDURES 5 1 BATTERY LOADING 5 2 CLOCK AND DATE ADJUSTMENT 6 3 CONNECTING THE CUFF TO THE MONITOR 6 4 APPLYING THE CUFF 7 5 BODY POSTURE DURING MEASUREMENT 7 6 T...

Страница 2: ...usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are awake and ac...

Страница 3: ...lectrical equipment Part 1 General requirements for basic safety and essential performance IEC60601 1 2 2007 EN 60601 1 2 2007 AC 2010 Medical electrical equipment Part 1 2 General requirements for ba...

Страница 4: ...o allow the blood circulation in your arm to recover Prolonged over inflation cuff pressure exceed 300 mmHg or maintained above15 mmHg for longer than 3 minutes of the bladder may cause ecchymoma of y...

Страница 5: ...nd complied with IEC 60601 1 EN 60601 1 UL 60601 1 and IEC 60601 1 2 EN 60601 1 2 UL 60601 1 2 is suitable for this monitor Please note that the monitor jack size hole 3 5mm center pin 1 0mm Please pa...

Страница 6: ...ode press the START and MEM button simultaneously for two seconds the month will blink at first Press the button START repeatedly the day hour and minute will blink in turn While the number is blinkin...

Страница 7: ...PECIFICATIONS to make sure that the appropriate cuff is used 2 Measuring on same arm each time 3 Do not move your arm body or the monitor and do not move the rubber tube during measurement 4 Stay quie...

Страница 8: ...rtbeat symbol if any will blink on the screen The result will be automatically stored in the monitor d After measurement the monitor will turn off automatically after 1 minute of no operation Alternat...

Страница 9: ...ntended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme and that the color scheme is meant only to discriminate between the different levels of b...

Страница 10: ...ened Apply the cuff correctly and try again Body posture was not correct during testing Review the body posture and testing sections of the instructions and re test LCD Display shows abnormal result S...

Страница 11: ...chnical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a minimum of 10 000 measu...

Страница 12: ...magnetic emissions The TMA 6000 is intended for use in the electromagnetic environment specified below The customer or the user of the TMA 6000 should assure that it is used in such an environment Emi...

Страница 13: ...requency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Tabl...

Страница 14: ...tions Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordles...

Страница 15: ...istance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3...