For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING 

Recommended separation distances between 

portable and mobile RF communications equipment and the TMA-6000 

The TMA-6000 is intended for use in an electromagnetic environment in which radiated RF 
disturbances are controlled. The customer or the user of the TMA-6000 can help prevent 
electromagnetic interference by maintaining a minimum distance between portable and 
mobile RF communications equipment (transmitters) and the TMA-6000 as recommended 
below, according to the maximum output power of the communications equipment. 

Separation distance according to frequency of transmitter 

Rated maximum 

output 

power of 

transmitter 

150 kHz to 80 MHz 

 

80 MHz to 800 MHz 

 

800 MHz to 2,5 GHz 

0,01 0.12  0.12  0.23 

0,1 0.38  0.38  0.73 

1 1.2  1.2 2.3 

10 3.8  3.8  7.3 

100 12  12  23 

For transmitters rated at a maximum output power not listed above, the recommended 
separation distance d in meters (m) can be determined using the equation applicable to the 
frequency of the transmitter, where P is the maximum output power rating of the transmitter 
in watts (W) according to the transmitter manufacturer. 
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range 
applies. 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is 
affected by absorption and reflection from structures, objects and people. 

 

 

P

d

2

.

1

=

P

d

2

.

1

=

P

d

3

.

2

=

Содержание TMA-6000

Страница 1: ...TIONS 3 NOTICE 4 SETUP AND OPERATING PROCEDURES 5 1 BATTERY LOADING 5 2 CLOCK AND DATE ADJUSTMENT 6 3 CONNECTING THE CUFF TO THE MONITOR 6 4 APPLYING THE CUFF 7 5 BODY POSTURE DURING MEASUREMENT 7 6 T...

Страница 2: ...usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are awake and ac...

Страница 3: ...lectrical equipment Part 1 General requirements for basic safety and essential performance IEC60601 1 2 2007 EN 60601 1 2 2007 AC 2010 Medical electrical equipment Part 1 2 General requirements for ba...

Страница 4: ...o allow the blood circulation in your arm to recover Prolonged over inflation cuff pressure exceed 300 mmHg or maintained above15 mmHg for longer than 3 minutes of the bladder may cause ecchymoma of y...

Страница 5: ...nd complied with IEC 60601 1 EN 60601 1 UL 60601 1 and IEC 60601 1 2 EN 60601 1 2 UL 60601 1 2 is suitable for this monitor Please note that the monitor jack size hole 3 5mm center pin 1 0mm Please pa...

Страница 6: ...ode press the START and MEM button simultaneously for two seconds the month will blink at first Press the button START repeatedly the day hour and minute will blink in turn While the number is blinkin...

Страница 7: ...PECIFICATIONS to make sure that the appropriate cuff is used 2 Measuring on same arm each time 3 Do not move your arm body or the monitor and do not move the rubber tube during measurement 4 Stay quie...

Страница 8: ...rtbeat symbol if any will blink on the screen The result will be automatically stored in the monitor d After measurement the monitor will turn off automatically after 1 minute of no operation Alternat...

Страница 9: ...ntended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme and that the color scheme is meant only to discriminate between the different levels of b...

Страница 10: ...ened Apply the cuff correctly and try again Body posture was not correct during testing Review the body posture and testing sections of the instructions and re test LCD Display shows abnormal result S...

Страница 11: ...chnical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a minimum of 10 000 measu...

Страница 12: ...magnetic emissions The TMA 6000 is intended for use in the electromagnetic environment specified below The customer or the user of the TMA 6000 should assure that it is used in such an environment Emi...

Страница 13: ...requency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Tabl...

Страница 14: ...tions Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordles...

Страница 15: ...istance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3...

Отзывы: