ST-402N User's Manual v 1.0.3
-
12
-
V.a.7)
Scheme 7/17
–
Two Tanks, Two Pumps
Installation 7/17 Operates:
The two collector pumps.
The two accumulative tanks.
One direction of the collectors' location.
Additional peripherals.
Installation Sensors:
The collector's sensor.
The Accumulation Tank sensors.
Additional Parameters to be Adjusted:
Valve Hysteresis.
The set temperature of tank 2.
The maximum temperature of tank 2.
Hysteresis of tank 2.
Operation algorithm.
Oscillation charging.
The oscillation pause time.
Maximum heating time Z2.
Deactivation delta of pump 2.
Activation delta of pump 2.
V.a.8)
Scheme 8/17
–
Two Tanks - Order
Installation 8/17 Operates:
The Collector Pump.
The second tank's pump.
Tank 1 with top and bottom circulation.
Tank 2.
One direction of the collectors' location.
Additional peripherals (not possible to cool down using the
DHW pump).
Installation Sensors:
The collector's sensor.
The two sensors of the main accumulation tank – top
and bottom.
The sensor of the additional accumulation tank.
Additional Parameters to be Adjusted:
The set temperature of tank 2.
The maximum temperature of tank 2.
Hysteresis of tank 2.
Operation Algorithm.
Deactivation delta of pump 2.
Activation delta of pump 2.
V.a.9)
Scheme 9/17
–
Heat Exchanger
Installation 9/17 Operates:
The Collector Pump.
The switching valve between the tank and the exchanger.
The Accumulation Tank.
The Heat Exchanger (heat Receiver).
One direction of the collectors' location.
Additional peripherals.
Installation Sensors:
The collector's sensor.
The Accumulation Tank's sensor.
The Heat Exchanger sensor.