Tech
-
11
-
Additional Parameters to be Adjusted:
Deactivation delta of pump 2.
Activation delta of pump 2.
V.a.4)
Scheme 4/17
–
Two Collectors, Valve
Installation 4/17 Operates:
The Collector Pump.
The valve switching between the collectors
The Accumulation Tank.
The two directions of the collectors' location.
Additional peripherals.
Installation Sensors:
The two collector sensors.
The Accumulation Tank's sensor.
Additional Parameters to be Adjusted:
Collector delta.
V.a.5)
Scheme 5/17
–
Reheating with Boiler
Installation 5/17 Operates:
The Collector Pump.
The Auxiliary Pump – tank-boiler (
Pump 2
).
The Accumulation Tank with top and bottom circulation.
One direction of the collectors' location.
Additional peripherals (not possible to cool down using the
DHW pump).
Installation Sensors:
The collector's sensor.
The two sensors of the Accumulation Tank – top and bottom,
The boiler temperature sensor.
Additional Parameters to be Adjusted (additional submenu in the
service menu):
Installation's options: reheating activation delta, from hour..., to hour..., energy release,
energy release threshold, release hysteresis, release solar pump.
V.a.6)
Scheme 6/17
–
Two Tanks, Valve
Installation 6/17 Operates:
The Collector Pump.
The valve switching between the tanks.
The two accumulative tanks.
One direction of the collectors' location.
Additional peripherals.
Installation Sensors:
The Collector's sensor.
The Accumulation Tank sensors.
Additional Parameters to be Adjusted:
The set temperature of tank 2.
The maximum temperature of tank 2.
Hysteresis of tank 2.
Oscillation charging.
The oscillation pause time.
Maximum heating time Z2.
Valve Hysteresis.