background image

  

 

R-MI-FAXL1  Rev.: 0  english version 

Series FLOMAT 

Sensor FLOMAT-XL + Converter XL1 

Instructions manual 

 

The art of measuring 

Содержание Converter XL1

Страница 1: ...R MI FAXL1 Rev 0 english version Series FLOMAT Sensor FLOMAT XL Converter XL1 Instructions manual The art of measuring...

Страница 2: ...nd safety with no obligation to update this manual Make sure this manual goes to the end user Keep this manual in a place where you can nd it when you need it In case of loss ask for a new manual or d...

Страница 3: ...Vibrations 10 4 7 Magnetic elds 10 4 8 Temperature 10 5 MOUNTING 11 5 1 Pipe adaptor mounting 11 5 2 Sensor mounting 13 5 3 Tightening torque 13 5 4 Electronic converter connection 13 5 5 Electronic c...

Страница 4: ...5 4 Current loop calibration 26 7 6 Visualization 27 7 7 Zero ow drift adjustment 27 7 8 Datalogger 28 7 9 Firmware updates 29 7 10 Con guration le 30 8 MAINTENANCE 31 9 TECHNICAL CHARACTERISTICS 32 1...

Страница 5: ...erpendicularly to the magnetic field sense this voltage V The electronic converter is based on the most advanced technology in digital signal processing in order to obtain accurate and reliable measur...

Страница 6: ...l the flowmeters have been verified in our calibration rigs to obtain the gain factor for each sensor 2 1 Unpacking Unpack the instrument carefully removing any remains of the packing 2 2 Storage temp...

Страница 7: ...inimum distance between the sensor and the element Several 90 coplanar bends Fully opened plug valve Fully opened butter y valve 90 elbow Several 90 non coplanar bends T accessory Total angle converge...

Страница 8: ...5 x DN 4 1 1 Mixtures If liquids of different conductivities are mixed it is necessary to install the sensor a minimum of 50 x DN from the point of mixture in order to obtain a uniform conductivity of...

Страница 9: ...ifference in level is higher than 5 m an air inlet valve should be installed after the sensor to avoid a vacuum effect that could damage the sensor 4 4 Pumps Pumps should be mounted upstream from the...

Страница 10: ...nsor The vibration level should be less than 2 2 g in the range of 20 150 Hz according to IEC 068 2 34 4 8 Temperature In open air installations it is recommended to install a protection to avoid dire...

Страница 11: ...daptor Before welding the adaptor to the pipe the sensor must be removed to avoid irreparable damage due to excessive temperatures There are two basic types of pipe adaptors with threaded or with ange...

Страница 12: ...meter for each DN Cut this label above the line corresponding to the DN of the pipe at a distance equal to the pipe thickness Peel off the bottom part of the label Once the pipe adaptor is placed into...

Страница 13: ...ensor length The axis of the pipe adaptor should be perfectly perpendicular to the pipe axis 5 2 Sensor mounting Once the pipe adaptor is mounted place the at seal in its position and install the sens...

Страница 14: ...from the cables with low level signals 4 20 mA or pulses To connect the cables peel the outside insulation to free the inner cables Then pass the cables through the cable glands and screw down in the...

Страница 15: ...lated It can be either active which means that the receiving device must be passive or passive which means that the receiver must supply the power for the current loop It is recommended to use a recep...

Страница 16: ...16 NOTE Never connect the load between entre terminals and The analog output could be damaged 6 3 Digital output wiring Terminal C Collector E Emitter Active output Passive output...

Страница 17: ...red if there is a ow and will remain green if there is no ow If it is con gured as alarm mode see page 26 the led will light red when the alarm is activated and green when it is not In the case of usi...

Страница 18: ...1 USB cable connection and software installation Extract the les from the Winsmeter XL1 zip to a new system folder Execute the Setup exe le and follow the steps for the installation In order to connec...

Страница 19: ...name of the port followed by XL1 and its serial number Then click Open Connect the USB cable at one end to the converter and at the other to the computer where the software is installed Power on the e...

Страница 20: ...ocked data can be read but not modi ed By default the device is unlocked All data can be modi ed by means of the program Winsmeter XL1 To set a password access to a section Installation or Programming...

Страница 21: ...21 Once done the following window will appear In the Password textbox a 4 numeric digit code should be entered and in the Con rm textbox the code is con rmed to avoid unintentional errors...

Страница 22: ...22 Once the password is con rmed press the Lock button and the section Installation or Programming will be locked The text Device locked will appear and the program returns to the home screen...

Страница 23: ...the locked passwords To unlock the section it is necessary to write the correct password and press Enter or the Open button The text Installation enabled or Programming enabled will appear at the bott...

Страница 24: ...nominal diameter DN and the ow direction can be con gured The Gain factor is composed of an integer and three decimals It must match the Fg parameter on the device label DN is the inner diameter of th...

Страница 25: ...selected the analog output will give a value between 4 mA and 20 mA proportional to ow rate when it is positive and it will give a value of 21 mA when the ow rate is negative Values for 4 mA and 20 m...

Страница 26: ...f alarm As in the analog output if the Bidirectional checkbox is selected the pulse output will be operative whether the ow rate is positive or negative If it is not selected the pulse output will be...

Страница 27: ...e of the analog output and the status of the digital output if con gured as alarm can also be shown It also has messages or warnings regarding the status of the ow meter such as empty pipe coil errors...

Страница 28: ...come effective Under these conditions the ow measured by the instrument will appear in the Measured ow box If this ow has an important zero drift the text Very high offset will appear To correct the o...

Страница 29: ...rmat which can be viewed directly with a spreadsheet 7 9 Firmware updates New rmware updates can be published in the website These updates contain improvements or bug xes that make that the equipment...

Страница 30: ...which the message Device programmed will appear The le is saved in the same folder where the Winsmeter XL1 software is located In the same way a con guration data le can be loaded into the device To d...

Страница 31: ...e Programming tab IMPORTANT The USB connection is used only for the con guration and commissioning of the device In no case it is intended to be used continuously as a normal mode of operation in an i...

Страница 32: ...re system Power consumption 5 W Analog output 4 20 mA Active or passive Galvanically isolated from the power supply Pulse output Opto isolated NPN bipolar transistor Vmax 30 VDC Imax 30 mA Maximum fre...

Страница 33: ...ot subject to conformity assessment are considered outside the scope of the directive and therefore they have not the CE mark according to pressure directive These devices are subject to applicable so...

Страница 34: ...34 11 DIMENSIONS FLOMAT XL R 2 DN A FL 4 400 113 5 246 5 500 1000 218 5 351 5 11200 2000 368 5 501 5 All dimensions in mm...

Страница 35: ...35 FLOMAT XL TF flange DN A FL 4 400 113 5 246 5 500 1000 218 5 351 5 11200 2000 368 5 501 5 All dimensions in mm...

Страница 36: ...36 DN A FL 4 400 113 5 246 5 500 1000 218 5 351 5 11200 2000 368 5 501 5 FLOMAT XL EN 1092 1 flange All dimensions in mm...

Страница 37: ...limentaci n Cambiar la fuente de alimentaci n La salida anal gica siempre indica 4 mA o 20 mA Programaci n inadecuada del rango de corriente Programar el rango correctamente ver p g 25 La salida anal...

Страница 38: ...38 ANNEX...

Страница 39: ...39...

Страница 40: ...bstances The devices sent for repair must enclose the corresponding form which can be lled in via website from the same After Sales section Warranty for repaired or replaced components applies 6 month...

Отзывы: