![TEC Infra-red STERLING Скачать руководство пользователя страница 9](http://html2.mh-extra.com/html/tec-infra-red/sterling/sterling_owners-manual_4025904009.webp)
Revised 08/04
8
Gas Connection
General Overview
WARNING:
THE GAS SUPPLY HOSE SHOULD BE
INSPECTED PRIOR TO EACH USE. DO NOT USE A GAS
HOSE THAT HAS ABRASION, CUTS OR EXCESSIVE
WEAR. IF ABRASION, CUTS OR EXCESSIVE WEAR IS
EVIDENT, THE GAS SUPPLY HOSE MUST BE REPLACED
BEFORE USE. REPLACEMENT ASSEMBLY MUST BE
SPECIFIED BY TEC.
WARNING:
WHEN YOUR GRILL IS STORED INDOORS,
REMOVE AND STORE THE LP GAS CYLINDER
OUTDOORS IN A PROTECTED, COOL AND DRY
LOCATION OUT OF REACH OF CHILDREN. THE
CYLINDER SHOULD NOT BE STORED IN A BUILDING,
GARAGE OR ANY OTHER ENCLOSED AREA.
Follow the procedures outlined in this section closely to
ensure safe and proper grill operation. The Sterling grill is
offered in one of two gas configurations: LP or Natural
gas. The pressure regulator and hose used for the LP gas
configuration varies depending on the type of base used.
Reference Table A.2 below for regulator specifications.
Grills that do not use LP gas with standard 20 lb. LP
cylinder must be installed by qualified personnel. This
includes all Natural gas and permanently installed units.
Gas regulators specified by TEC should be used at all
times.
PLEASE NOTE: When any burner using propane fuel
exceeds the capacity of the propane cylinder to vaporize
the fuel, the cylinder pressure can decrease to the extent
that the appliance will not burn properly.
Refer to Table A.2 below for gas supply specifications or
see rating plate located at the grill’s right rear corner
below Drip Tray.
LP Gas Cylinder Safety
WARNING:
WHEN PURCHASED FOR USE WITH LP
GAS, THE STERLING GRILL COMES WITH A
REGULATOR ASSEMBLY THAT USES A TYPE I CYLINDER
CONNECTION DEVICE. THIS DEVICE SHOULD ONLY BE
USED WITH A TYPE I TANK VALVE CYLINDER
CONNECTION.
NOTICE:
AN LP GAS CYLINDER IS NOT PROVIDED
FROM THE FACTORY WITH THIS GRILL. HOWEVER,
ONLY APPROVED 20 LB. LP GAS CYLINDERS
CONSTRUCTED AND MARKED IN ACCORDANCE WITH
THE
SPECIFICATIONS FOR LP GAS CYLINDERS OF
THE U.S. DEPARTMENT OF TRANSPORTATION (D.O.T)
OR NATIONAL STANDARD OF CANADA, CAN/CGA-B339,
CYLINDERS, SPHERES AND TUBES FOR THE
TRANSPORTATION OF DANGEROUS GOODS; AND
COMMISSION, SHOULD BE USED.
ALL APPROVED
CYLINDERS MUST BE EQUIPPED WITH AN INTEGRAL
COLLAR DESIGNED TO PROTECT THE CYLINDER
VALVE FROM DAMAGE, AS WELL AS A LISTED
OVERFILL PROTECTION DEVICE. DO NOT USE OR TRY
TO REPAIR A DAMAGED LP GAS CYLINDER AT ANY
TIME. CONTACT YOUR LOCAL LP GAS SUPPLIER FOR
REPLACEMENT. ALSO, YOU SHOULD ALWAYS
OBSERVE THE FOLLOWING PRECAUTIONS:
■
Store spare or extra gas cylinders at least 15 feet from
this grill or other open flame, heat-producing
appliance or heat source.
■
Do not fill your gas cylinder beyond
3
/
4
full.
■
Gas cylinders come with a pressure relief valve. If a
cylinder is subjected to excess heat, the relief valve
will open and let highly flammable gas vapor and/or
liquid escape. Therefore, do not store gas cylinders
near an open flame or source of heat. Store cylinders
only in well ventilated areas.
WARNING:
FAILURE TO FOLLOW THE ABOVE
PRECAUTIONS COULD RESULT IN A FIRE CAUSING
DEATH OR SERIOUS INJURY OR PROPERTY DAMAGE.
GAS, REGULATOR
SUPPLY PRESSURE
OPERATING PRESSURE
MAIN BURNER
BURNER OUTPUT
AND BASE TYPE
(IN. WC (kPa), MAX/MIN)
(IN. WC (kPa))
ORIFICE SIZE (DMS / DIA.)
(BTU/HR. (W)/EA.)
Natural
14.0 (3.4)/5.0 (1.2)
4.0 (1.0)
46 (0.0810")
18,500 (5,422)
model RV-47L (NG)
stationary or post
LP
14.0 (3.4)/12.0 (3.0)
11.0 (2.7)
55 (0.0520")
18,500 (5,422)
model RV-47L (LP)
stationary or post
LP
125 psi (861), max
11.0 (2.7)
55 (0.0520")
18,500 (5,422)
model 150 w/ hose
pedestal or cabinet
Table A.2.
Gas Supply Specifications
Содержание STERLING
Страница 20: ...19 19 Appendix A Sterling Build in Specifications continued SIDE VIEW...