Design and function
MIG/MAG welding
40
299-031000-TWD01
18.10.2016
5.3.5
MIG/MAG operating point
5.3.5.1
Selecting the welding parameter display mode
The operating point (welding power) can be displayed or set as the welding current, material thickness or
wire speed.
Figure 5-17
5.3.5.2
Operating point setting using material thickness
The process of setting the operating point by means of the panel thickness parameter is described as an
example below.
Plate thickness details in welding programs generally refer to fillet welds in the PB welding position. They
should be regarded as guideline values and may differ in other welding positions.
Figure 5-18
5.3.5.3
Arc length correction setting
Setting range: -5 V to +5 V
Figure 5-19
The basic settings are now completed. Other welding parameters have already been set optimally