Appendix B
Parameter overview
– setting information
76
299-031000-TWD01
18.10.2016
12
Appendix B
12.1 Parameter overview
– setting information
W
eldin
g
dat
a displ
ay
(3
-d
igit
)
Parameters/function
Setting range
S
tand
ar
d
(ex
w
o
rks
)
Min.
Max.
Un
it
MIG/MAG
Gas pre-flow time
0,5
0,1
- 20,0
s
Dynamic correction
0
-40
-
40
Gas post-flow time
0,5
0,0
- 20,0
s
Wire burn-back
0
-50
-
50
TIG
Gas pre-flow time
0,5
0,0
-
5,0
s
Ignition current
1
-
200
%
Up-slope time
1,0
0,0
- 20,0
s
Down-slope time
0,0
- 20,0
s
End current
20
1
-
200
%
Gas post-flow time
0,5
0,1
- 20,0
s
MMA
Arcforce correction
0
-10
-
10
Hot start current
50
-
200
%
Hot start time
0,5
0,1
- 20,0
s
Basic parameters (independent of procedure)
Cable resistance 1
8
0
-
60
mΩ
Time-based power-saving mode
off
5
-
60
min.
Service menu
Power-saving mode active