Machine description
– quick overview
Machine control
– Operating elements
299-020100-TWD01
18.03.2016
17
Item Symbol
Description
0
10
Excess temperature signal light
In case of excess temperature, temperature monitors de-activate the power unit, and
the excess temperature control lamp comes on. Once the machine has cooled down,
welding can continue without any further measures.
11
Collective interference signal light
For error messages, - See 7 chapter
4.3.1
Welding data display
The machine will be calibrated for approx. 2 seconds each time it is switched on. This will be indicated by
on the display. Subsequently, the value set for the dynamic power adjustment will be displayed for
approx. 3 s- See 7.5 chapter.
The value shown on welding data display depends on the selected parameter (current or time). After
approx. 5 s the display switches back to the welding current nominal value.
Advanced parameters are shown by the alternate display of the welding parameter with the respective
value (the parameter code illuminates for approx. 2 s, parameter value illuminates for approx. 2 s). After
approx. 60 s the display switches back to the welding current nominal value.
In case of failures, error codes are shown on the display.