background image

11

BRC-60 drop-in battery charger 

This stylish desktop drop-in charging station makes it convenient 

and  easy  to  recharge  both  Sapphire  Pendant  and  Handheld 

Microphones.  Charge  one  IRH-35  handheld  transmitter  and  up 

to  two  IRT-60  Sapphire  transmitters  simultaneously.  Charging 

indicator  lights  illuminate  Red  when  charging,  and  Green  when 

fully charged. The power LED illuminates Blue when plugged in.

ICS-55 ceiling sensor

sensor cable

The ceiling sensor is the preferred infrared sensor for optimum 

performance.  This  is  the  unit  that  needs  to  be  installed  on  the 

ceiling. It comes with a mounting/support bracket and 50 feet of 

plenum rated cable with RCA connector on each end. The ideal 

location for the dome sensor would be in the center of the ceiling. 

This will provide a clear signal path for the IR transmission from 

the transmitter to the dome sensor without obstruction. In addition, 

you will have 360° coverage and will minimize the transmission 

distance  for  more  reliable  performance.  It  collects  the  infrared 

transmission signal via 6 large detecting diodes. 

A cable connects the sensor to the receiver. The cable is dual-

shielded with a male RCA connector on each end and is plenum 

rated. 

Green light indicates that 

the sensor is receiving 

power from the receiver. 

power “on” LED

components

Содержание Matrix IRP-1650/LS4

Страница 1: ...Amplifier Audio Mixer Infrared Microphone Receiver IMA 120 MatrixTM CLASSROOM AUDIO SYSTEM INSTALLER AND OPERATIONS MANUAL rev20200324 P N UMM 120...

Страница 2: ...notes Date of Purchase Model Number Serial Number Notes 2...

Страница 3: ...ed manufacturing methodology and uses only premium quality components to assure many years of reliable performance We appreciate your confidence by your selection of our product It is TeachLogic s int...

Страница 4: ...it will not be subjected to falling objects or water entry Internal Service User should not attempt to service this product All internal service must be accomplished by a qualified technician Electri...

Страница 5: ...of Ceiling Sensor Installation of Ceiling Speakers Installation of Wall Mount Speakers Final Connection of Speakers Page Mute Pass Through CPS 120 CPR 125 Remote Control Panel RS 232 Features RS 232...

Страница 6: ...ared light beams to the sensor located in the corner of the room When you talk into the microphone the microphone element modulates the light beam causing it to flicker in sync with your speech The se...

Страница 7: ...eceiver amplifier IMA 120 The receiver amplifier processes the signal and produces an analog signal of your voice for output to the sound field speaker system 1 Power on off Indicator 2 Page sensitivi...

Страница 8: ...EVICES LESSON CAPTURE RECORDER Wall mounted call button THIRD PARTY INTERCOM PAGING SPEAKER 3RD PARTY INTERCOM PAGING SYSTEM WALL PANEL Emergency Normal Output to front office intercom panel via exist...

Страница 9: ...icrophone and a unique free air suspension system With a built in breath filter the Sapphire can function as a pass around hand mic The strategic alignment of the emitting diodes assures reliable conn...

Страница 10: ...Diodes at top and bottom of handle for increased Coverage 2 Top aimed out 6 Bottom 360 2 Bottom aimed down 360 IR radiation for assured connectivity Two AA Duracell rechargeable NiMH batteries IRT 60...

Страница 11: ...stalled on the ceiling It comes with a mounting support bracket and 50 feet of plenum rated cable with RCA connector on each end The ideal location for the dome sensor would be in the center of the ce...

Страница 12: ...ssion from the transmitter to the dome sensor without obstruction In addition you will have 360 coverage and will minimize the transmission distance for more reliable performance Installation 1 Attach...

Страница 13: ...systems you plan to connect to the amplifier such as audio devices intercom connections fire alarm noting how the wiring needs to run Microphones Charger Confirm microphone charging location for daily...

Страница 14: ...all speaker grille and remove any soil or fingerprints 17 Repeat steps 7 16 for other speakers 18 See final connection section to finish installation Mounting Screws 1 Lay ceiling tile face down on cl...

Страница 15: ...aker with the tweeter in upper position 7 Secure speaker in bracket with the hand fasteners 8 Orient each speaker toward the center of that half of the listening area and tighten fasteners 30 20 33 45...

Страница 16: ...ing iron tin the wire ends 4 Unplug the phoenix connector from amplifier Reference amplifier insert diagram on amplifier Figure H wire with printed writing into either outside terminal 5 Plug the othe...

Страница 17: ...ge impedance or 25 25 160 000 CONNECTION 1 Tap Splice page speaker s wire and connect to our amp via 2 pin Phoenix connector 2 Determine the signal level of the paging system 25v 70v or 100v and set t...

Страница 18: ...partment that is not easily assessed by the user No set up is required for these touch panels to operate They are preprogrammed right out of the box remote control of audio inputs CPR 125 The CPR 125...

Страница 19: ...N 6 When the LCD screen light is ON you can press any of the eight available input source buttons to adjust the volume CPS 120 CPR 125 panel operation EXAMPLE Aux input volume adjust Please note that...

Страница 20: ...digram and Hex code chart to ensure your control panel is wired and programmed properly IMPORTANT When any remote panel is connected RS 232 switch must be in ON position When panel is not connected RS...

Страница 21: ...device This display indicates that your mobile device and Touch Panel are in the pairing process This display indicated your device and the Touch Panel are paired Please note that your device will al...

Страница 22: ...ounted button was being pressed The amplifier functions normally during the alert e g there is no change to audio input output volume change nor does the system produce any sound KEY SPECS Contact clo...

Страница 23: ...st the mute function by briefly pressing the Sapphire TL power button once flashing blue 12 Briefly press power button again The light should return to solid blue 13 Upon completion of performance tes...

Страница 24: ...holding a charge Check for IR transmission If the amplifier is receiving a signal presence the mic channel indicator will be illuminated Orange Ensure the Green LED on the ceiling sensor is illuminate...

Страница 25: ...25 Please refer to www teachlogic com warranty warranty...

Страница 26: ...2 1 760 631 7800 support teachlogic com teachlogic com...

Отзывы: