Content
Command
Command No. Byte
Parameter
Note
Zone settings
Set zone number
7200
1
1 to 5
(resets to 1 when power turned on/off )
The zone set by this
can be changed
with the following
commands.
Enable zone
7201
1
0: Disabled, 1: Enabled
Zone range starting point
7202
4
0 to 99999
Zone range ending point
7203
4
0 to 99999
Load high limit (HI)
7204
4
±99999
Load low limit (LO)
7205
4
±99999
Displacement high limit (HI)
7206
4
0 to 99999
This can be set when
the X axis is set to
displacement.
Displacement low limit (LO)
7207
4
0 to 99999
Judgment method
7208
1
0: Constant comparison, 1: Sample,
2: Peak, 3: Bottom, 4: Peak-to-peak,
5: Average value, 6: Maximum,
7: Minimum, 8: Inflection point
Maximum/
minimum
Load difference (LOAD DIF.)
7211
4
±99999
Scaling factor
7212
1
00 to 99 (input without decimal point)
(0.0 to 9.9)
Values higher than
9.9 automatically
rounded to 9.9.
Number of detections
(COUNT)
7213
1
1 to 10
Values higher than
10 automatically
rounded to 10.
Inflection point
(INFLECTION)
Detection starting load
(STARTING LOAD)
7220
4
±99999
Detection extent A
(WIDTH A)
7221
4
1 to 9999
Detection extent B
(WIDTH B)
7222
4
1 to 9999
Load difference (LOAD DIF.)
7223
4
±99999
Offset extent (OFFSET)
7224
4
0 to 99
Message communication (measurement data commands)
Content
Command
Command
No.
Service Transmitted data (in word* units)
Zone display
Zone 1
300
R
Start pos End pos Load(Lo) Load(Hi) Disp(Lo)
Disp(Hi)
Zone 2
301
R
Start pos End pos Load(Lo) Load(Hi) Disp(Lo)
Disp(Hi)
Zone 3
302
R
Start pos End pos Load(Lo) Load(Hi) Disp(Lo)
Disp(Hi)
Zone 4
303
R
Start pos End pos Load(Lo) Load(Hi) Disp(Lo)
Disp(Hi)
Zone 5
304
R
Start pos End pos Load(Lo) Load(Hi) Disp(Lo)
Disp(Hi)
Measurement
waveform
Measurement range
305
R
Start pos End pos
Load measurement
waveform (load)
310 to 319
R
1 block = 224 words* (10 blocks total)
Load measurement
waveform (displacement)
320 to 329
R
1 block = 224 words* (10 blocks total)
Load measurement time 330 to 339
R
1 block = 224 words* (10 blocks total)
Band waveform
Band waveform range
306
R/W
Start pos End pos
Load band waveform
(low limit)
350 to 359
R/W
1 block = 224 words* (10 blocks total)
Load band waveform
360 to 369
R/W
1 block = 224 words* (10 blocks total)
o
Start pos and End pos units are not physical units. They are dot positions on the X axis. Values are in the image range (0–2239) on
the X axis.
*1 word is 2 bytes (little-endian)