Content
Command
Command No. Byte
Parameter
Note
Linearization
Enable/disable
linearization
1200
1
0: Disabled, 1: Enabled
Select linearization point
1201
1
1 to 5
The point desig-
nated by this can be
changed with the fol-
lowing commands.
Selection point enabled/
disabled
1202
1
0: Disabled, 1: Enabled
Sensor output value for
calibration point
1203
4
4-digit sensor output value (no decimal)
(0 < setting value < rated output value)
Setting this value will
calculate the load
value from the current
calibration value and
make it the default
output load value for
the calibration point.
Output load value for
calibration point (equiva-
lent input)
1204
4
±99999
An error will result if
the difference with
the default value is
5% or more.
Output load value for
calibration point (actual
load input
1205
4
±99999
D/A
D/A output setting
1301
1
0: Voltage, 1: Current
D/A max. voltage
1302
1
1 to 10
D/A Zero
1303
4
±99999
D/A full scale
1304
4
±99999
TEDS sensor
Serial number
6001
4
BCD
Maximum rated capacity
6002
4
BCD (highest byte
is decimal point
position)
Maximum rated output
6003
4
BCD (highest byte
is decimal point
position)
Sensor impedance
6004
4
BCD (highest byte
is decimal point
position)
Max. excitation level
6005
4
BCD (highest byte
is decimal point
position)
Calibration date
(CAL. DATE)
6006
4
BCD
Model number
6007
2
BCD
Displacement
sensor
Reset zero balancing
(voltage)
1500
1
1: Execute
Unit shown
1501
1
1: μm, 2: mm, 3: cm, 4: m, 5: rad, 6: deg,
0: None
Input mode
1502
1
0: Pulse, 1: Voltage
Sensor input logic
1503
1
0: Standard, 1: Reversed
Zero balancing
1504
1
1: Execute
Displacement decimal
point position
1505
1
0: None, 1: 0.0, 2: 0.00 3: 0.000, 4: 0.0000
2. Communication functions