background image

Charging the batteries

The Te Pari Revolution Dosing Gun is supplied with an intelligent charger that can recharge both 18650 
lithium-ion batteries at once. 

 

ʵ

Remove the battery clip from the base of the gun handle by squeezing in both sides of the clip and gently pulling the clip out.

 

ʵ

Fit each of the batteries into the charger by pulling down the spring loaded retainer, slotting the battery in, and then releasing the 
retainer. The negative terminals go on to the spring loaded end, with the positive terminals going nearest the lights.

 

ʵ

Connect the charger to a standard mains supply using the cable provided and switch on. The charger’s lights will run up and down 
while the battery type, state, and charge required is determined. A 12-volt cigarette lighter cable is also provided to power the 
charger in a vehicle. The charger’s lights will flash slowly in orange showing the charge progress. When all three LED lights are lit a 
steady green the batteries are fully charged and ready for use.

 

ʵ

Before reloading the batteries, ensure that the contacts inside the gun’s battery clip are clean and dry. 

 

ʵ

Squeezing the sides of the battery clip, push it back into the gun handle. The clip only fits into the gun in one direction; with the 
curved end facing forwards.

 

ʵ

Ensure that the polarity symbols match (+ to + and - to -) as marked on the clip and the batteries.

A.  Gun handle bottom

B.  Battery clip. Squeeze the sides of the 

tabs on the clip to remove or refit into the 
handle. Note the white terminal markings.

C.  The two lithium-ion 18650 batteries. On 

this type, the black band is on the positive 
end, but this may vary from other makes, 
so be sure to check before fitting.

D.  The curved end of the clip goes to the 

curved end of the handle when refitting 
the battery clip.

E.  Orange flashing lights showing that the 

batteries are charging and their state of 
charge.

F.  Three green steady lights mean the 

batteries are fully charged and ready for 
use.

Note: Please use only the supplied batteries.

8

Te Pari Revolution Dosing Gun

A

B

C

D

D

E

F

www.tepari.com  Freephone 0800 837 274

Содержание Revolution G10

Страница 1: ...TE PARI REVOLUTION 2018 Operational Manual G10 and G20 models...

Страница 2: ...ion Dosing Gun cautions 15 The Te Pari Revolution Dosing Gun Congratulations on your purchase of the new Te Pari Revolution Dosing Gun This digital self powered dosing gun allows you to deliver fully...

Страница 3: ...battery charger C 12 volt power supply for the battery charger D Mains power supply for the battery charger E Spares kit with 1x piston O ring inlet and outlet valve assemblies and valve retainer C c...

Страница 4: ...or decrease values and change a selection when displayed Most setting changes are made using these buttons Power button Click once to switch on The Te Pari logo followed by the gun model and 2 brief s...

Страница 5: ...faster speeds for less viscose liquids Dosing speed With the screen displaying the dosing speed icon arrows pointing left press the up arrow to increase the dosing speed or the down arrow to decrease...

Страница 6: ...show the process is complete The gun saves the changes and automatically returns to the main screen Note When using the 14 ml barrel dose increments change to 0 5 ml Barrel Change Sequence The barrel...

Страница 7: ...ith the tick highlighted press the menu button The display will return to the main menu and the number of doses and volume statistics will be reset to 0 7 Te Pari Revolution Dosing Gun www tepari com...

Страница 8: ...a steady green the batteries are fully charged and ready for use Before reloading the batteries ensure that the contacts inside the gun s battery clip are clean and dry Squeezing the sides of the batt...

Страница 9: ...Te Pari Scale for auto dosing as shown on page 10 Ensure that the gun s Wi Fi is enabled to allow the gun to automatically connect to the scale Each time a weight is recorded the scale will calculate...

Страница 10: ...keypad 5 Type Select calculated does or fixed dose using press once to select calculated dose and again to select fixed dose Rate Set using numerals and xxml xxxxkg ml Per Kg 6 Using arrow keys scroll...

Страница 11: ...valve remove the nozzle and cap then use a small screwdriver to release the C shaped valve retainer being careful not to damage it Be sure to refit it after cleaning as the outlet valve will not funct...

Страница 12: ...e wrong way around Inlet assembly entry hose end A Inlet valve connector B Inlet valve and spring The inlet valve is the larger of the two valves 70 ml barrel only C Inlet valve housing Outlet assembl...

Страница 13: ...n to modify products previously manufactured The company is not responsible for damage that occurs as a result of 1 failure to follow the instructions that came with the product 2 accident misuse abus...

Страница 14: ...hone 0800 837 274 Warranty reply card Te Pari Revolution Dosing Gun Please complete all details on the reverse and post to Te Pari Products office Te Pari Products Ltd New Zealand Head Office PO Box 2...

Страница 15: ...sed batteries according to the manufacturer s instructions Do not heat above 50 C 122 F Do not dispose of in fire or crush puncture or directly short circuit Keep batteries clean and dry Thank you for...

Страница 16: ...Te Pari Products Ltd 9 Endeavour Crescent North Oamaru Business Park Oamaru 9444 New Zealand Sales Email sales tepari com NZ Freephone 0800 837 274 or 64 3 433 077 www tepari com...

Отзывы: