Te Pari - www.tepari.com - FREEPHONE 0800 837 274
HD3 Sheep Handler Installation Manual
1214-V1
25
Racewell HD
SHEEP HANDLING SYSTEMS
SYMPTOM
The indicator displays ------------
Possible causes
Possible solutions
There is a problem with the loadbars
Contact the manufacturer
SYMPTOM
Indicator readout is fluctuating or not zeroing
Possible causes
Possible solutions
Plugs not completely connected
Plugs are damp
Battery is not adequately charged
Unit is damp
Electrical interference
Check the plug that goes over the loadbar collar is not
preventing the pins from engaging properly
Check loadbar cables are firmly in place, don’t over tighten
Check for moisture - clean with methylated spirits
Ensure dust caps are screwed together
Check battery charge state
Check indicator to unit cord
Electrical interference from a short on a electric fence can
affect your indicator
Battery and unit charges must be kept dry
SYMPTOM
Not automatically drafting or releasing
Possible causes
Possible solutions
Comms cable fault
Incorrect indicator settings
Communication cable from indicator to unit is damaged
or has dirty terminals - clean terminals with CRC
Communications cable is in the wrong port (Tru-Test)
Check your indicator settings are correct
SYMPTOM
Tru-Test indicator displays “Wait for Trigger”
Possible causes
Possible solutions
Dirty eyes
Faulty “Y” or Comms cable
Clean eyes
Check the “Y” and Communications cables and the cables
pins for damage, replace if required
SYMPTOM
Indicator not zeroing
Possible causes
Possible solutions
Tension in loadbars
Refer to the scale manual
Loosen 4 top bolts on loadbars, if they settle theymay
require a washer in 1 corner
Loadbars may require servicing
SYMPTOM
Eyes are not working
Possible causes
Possible solutions
Faulty eye switch
Dirty or broken eye
Eye cables broken or frayed
Replace
Clean and re-check, replace if required
Replace cable from autobox to eyes