4. Processor Heat sink Module (PHM) Sub-Assemblyfor Factory and Field Replaceable Unit (FRU)
4.4.6 PHM Assembly to Socket
Set all four Anti-Tilt wires into the locked position. (Outward position)
Verify that all four Anti-Tilt wires are in the locked position before tightening screws
. If anti-tilt wires are not in locked
positioned the anti tilt feature will not function properly and damage may occur