Connecting Contact Alarms to a Fusion Wideband System
7-58
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
Using a Base Station to Monitor Fusion Wideband
NOTE:
The BTS must be configured, by the carrier, for contact closure monitoring
prior to connecting a Fusion Wideband Main Hub to it.
When you connect a BTS to Fusion Wideband, the Fusion Wideband Main Hub is the
output of the alarms (alarm source) and the BTS is the input (alarm sense), as shown
in Figure 7-34. An interface cable is required between the daisy-chain cable and the
BTS. Because BTS alarm interface pinouts and Fusion Wideband-to-BTS distances
vary, this cable is often custom and wired on-site. Refer to Section 3.2.1 for Alarm
Contact details (Normally Closed).
Figure 7-34
Using a BTS to Monitor Fusion Wideband
NOTE:
For normally open contacts, the fault and warning contacts need to
be wired in parallel with other Main Hubs.
NOTE:
TE does not recommend using normally open contacts.
(custom made, on-site)
Band 1
Band 2
Band 3
UL1
UL2
UL3
DL1
DL2
DL3
AC Power
Alarms
Band 1
Band 2
Band 3
UL1
UL2
UL3
DL1
DL2
DL3
AC Power
Alarms
BTS
Interface
Cable
Alarm
Sense
Alarm
Source
Alarm
Source
5-port Alarm Daisy-Chain Cable
Содержание InterReach Fusion ADCP-77-044
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 203: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620616 0 20 Rev F CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 210: ...A 10 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...
Страница 216: ...B 6 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...