![TE Connectivity InterReach Fusion ADCP-77-044 Скачать руководство пользователя страница 142](http://html2.mh-extra.com/html/te-connectivity/interreach-fusion-adcp-77-044/interreach-fusion-adcp-77-044_manual_4998676142.webp)
Fusion Wideband Installation Procedures
7-36
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
7.4.4
Configuring the Fusion Wideband System
Before the system can operate properly, use AdminBrowser to program the Fusion
Wideband Main Hub with the frequency bands that are to be distributed. The Hub
must be programmed with the same frequencies as the RAU used.
NOTE:
The frequency bands should automatically be set on power up and
this step should not be required.
Considerations:
• The AdminBrowser software, described in the
AdminBrowser User Manual
(PN D-620607-0-20), must be running on a PC/laptop.
• Crossover Ethernet cable with male connectors required.
Connecting a PC to the Main Hub to Run AdminBrowser
1.
Connect the AC power cord to the Hub.
Make sure the Hub is grounded through the ground lug on the AC power and
the frame ground lug as required. The warranty does not cover damage
caused when an ungrounded Hub is powered on.
2.
Plug the power cord into an AC power outlet.
3.
Verify that all cables are properly connected on the Hub.
4.
Turn on the power to the Hub.
Table 7-7
Troubleshooting RAU LEDs During Installation
During
Installation
LED
State
Action
Impact
The RAU is connected
to the Fusion Wide-
band Expansion Hub,
which is powered on
LINK
Off
Check CATV cable.
No power to the RAU.
ALARM
Off
LINK
Green
• Check CATV cable
• Check Hub LEDs
Refer to page 7-31, item 2 in
Table 7-6.
• Use AdminBrowser to determine the
problem.
The RAU is off-line.
ALARM
Red
LINK
Red from
green, after
cables are
connected for
60 seconds
• Check CATV cable.
• Check the Hub LEDs.
• Use AdminBrowser to determine the
problem.
No communications
between the RAU and the
Hub.
ALARM
Red
Содержание InterReach Fusion ADCP-77-044
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 203: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620616 0 20 Rev F CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 210: ...A 10 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...
Страница 216: ...B 6 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...