Install the RF Module(s)
Page 42
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd
TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013
c
Connect the LVDS Cables to the RF Module.
i
If available, connect the MOD N DIV LVDS Cable to the DIV receptacle of the lower RF
Module by inserting and sliding in until fully seated. If DIV receptacle is not available,
constrain the MOD N DIV LVDS Cable to accompanying cables using a tie wrap so it
cannot be pinched or prevent the PRU door from closing.
ii
If available, connect the MOD N PRIM LVDS Cable to the PRIM receptacle of the lower
RF Module by inserting and sliding in until fully seated. If DIV receptacle is not
available, constrain the N PRIM LVDS Cable to accompanying cables using a tie wrap
so it cannot be pinched or prevent the PRU door from closing.
iii
If available, connect the MOD N DIV LVDS Cable to the DIV receptacle of the upper RF
Module by inserting and sliding in until fully seated. If DIV receptacle is not available,
constrain the MOD N DIV LVDS Cable to accompanying cables using a tie wrap so it
cannot be pinched or prevent the PRU door from closing.
iv
If available, connect the MOD N PRIM LVDS Cable to the PRIM receptacle of the upper
RF Module by inserting and sliding in until fully seated. If DIV receptacle is not
available, constrain the N PRIM LVDS Cable to accompanying cables using a tie wrap
so it cannot be pinched or prevent the PRU door from closing.
NOTE:
Full
insertion
can
be
recognized
by
an
audible
click
as
the
LVDS
Cable
Connector
locks
into
the
RF
Module
Receptacle.
This
can
be
verified
by
lightly
pulling
back
on
the
LVDS
connector
while
making
sure
not
to
depress
the
release
trigger.
When
fully
inserted,
the
cable
should
not
be
able
to
be
removed
from
the
receptacle.
d
Connect the Power cable to the RF Module.
i
Connect the Power Cable Connector to the PWR receptacle of the lower RF Module by
inserting and sliding in until fully seated.
ii
If available, connect the Power Cable Connector to the PWR receptacle of the upper RF
Module by inserting and sliding in until fully seated. If PWR receptacle is not available,
constrain the Power Cable to accompanying cables using a tie wrap so it cannot be
pinched or prevent the PRU door from closing.
NOTE:
Full
insertion
can
be
recognized
by
an
audible
click
as
the
Power
Cable
Connector
locks
into
the
RF
Module
Receptacle.
This
can
be
verified
by
lightly
pulling
back
on
the
Power
Cable
Connector
while
making
sure
not
to
depress
the
release
triggers
on
the
ends
of
the
connector.
When
fully
inserted,
the
cable
should
not
be
able
to
be
removed
from
the
receptacle.
Refer to the graphic that corresponds to the RF Module being installed in a dual‐slot:
•
Dual‐Bay Dual‐Slot RF Module:
Figure 23 on Page 43
•
Dual‐Slot 40W RF Module:
Figure 24 on Page 44
.
Содержание FlexWave Prism
Страница 49: ......
Страница 50: ...www te com wireless...