Install the RF Module(s)
Page 38
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd
TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013
Connecting
Cables
in
a
Single
‐
Slot
RF
Module
Installation
1
Position the cables so that they are under the right edge of the RF Module, pointing up.
2
Follow the rules listed in
“Understanding the RF Module Cables” on page 15
.
3
Working from the bottom connector up, connect the RF Module cables, as follows:
a
Connect the MOD N TX1/RX1 cable to the RF Module.
i
If a TX1/RX1 RF Module connection is available, insert the N‐Style Plug of the MOD N
TX1/RX1 cable into the TX1/RX1 N‐Style Jack of the RF Module. If RF Module
connection is not available, constrain the MOD N TX1/RX1 cable to accompanying
cables using a tie wrap so it cannot be pinched or prevent the PRU door from closing.
ii
Turn the coupling nut of the plug clockwise to thread onto the jack and finger‐tighten.
iii
Torque coupling nut to 8 +/‐ 1 in‐lbs to ensure full connection.
NOTE:
Insufficient
torque
applied
to
RF
Module
connections
can
result
in
elevated
insertion/return
loss
and
higher
than
normal
VSWR
reported
by
the
system.
b
Connect the MOD N TX0/RX0 cable to the RF Module.
i
Insert the N‐Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N‐Style Jack of
the RF Module.
ii
Turn the coupling nut of the plug clockwise to thread onto the jack and finger‐tighten.
iii
Torque coupling nut to 8 +/‐ 1 in‐lbs to ensure full connection.
NOTE:
Insufficient
torque
applied
to
RF
Module
connections
can
result
in
elevated
insertion/return
loss
and
higher
than
normal
VSWR
reported
by
the
system.
c
Connect the LVDS Cables to the RF Module.
i
Connect the MOD N DIV LVDS Cable to the DIV receptacle of the RF Module by
inserting and sliding in until fully seated.
NOTE:
Always
connect
the
Diversity
LVDS
Cable
with
the
RF
Module.
ii
Connect the MOD N PRIM LVDS Cable to the PRIM connector, following the same steps
as above.
NOTE:
Full
insertion
can
be
recognized
by
an
audible
click
as
the
LVDS
Cable
Connector
locks
into
the
RF
Module
Receptacle.
This
can
be
verified
by
lightly
pulling
back
on
the
LVDS
connector
while
making
sure
not
to
depress
the
release
trigger.
When
fully
inserted,
the
cable
should
not
be
able
to
be
removed
from
the
receptacle.
d
Connect the Power Cable Connector to the PWR receptacle of the RF Module by inserting
and sliding in until fully seated.
NOTE:
Full
insertion
can
be
recognized
by
an
audible
click
as
the
Power
Cable
Connector
locks
into
the
RF
Module
Receptacle.
This
can
be
verified
by
lightly
pulling
back
on
the
Power
Cable
Connector
while
making
sure
not
to
depress
the
release
triggers
on
the
ends
of
the
connector.
When
fully
inserted,
the
cable
should
not
be
able
to
be
removed
from
the
receptacle.