ADCP-96-088 • Issue 2 • 6/2013
Page 12
© 2013, Tyco Electronics Corporation. All Rights Reserved.
Use the following procedure to mount the cabinet on the FMS:
1. Use a 3/16-inch hex-key to remove the screws that secure the access covers to the front and
back sides of the cabinet ground spacer/riser as shown in
.
Figure 6. Removing Access Covers From Ground Spacer/Riser
2. Remove the access covers from the ground spacer/riser and set aside both the covers and
the screws for reuse.
3. Mount the FMS adapter cover on the FMS and secure using the two capscrews and flat
washers provided. Tighten each capscrew securely.
4. Place the isolation gasket (provided with cabinet) on the adapter cover and align the holes
in the gasket with the holes in the adapter cover. Make sure the side of the gasket with the
cut-out section aligns with the cut-out in the adapter cover.
5. If a ground spacer/riser (optional accessory) will be installed, place the spacer in position
for mounting on the adapter cover. The isolation gasket installed in step 4 should remain in
place between the adapter cover and ground spacer. If a ground spacer will not be
installed, proceed to step 8.
6. Align the mounting holes in the spacer/riser with the mounting holes in the adapter cover.
7. Secure the spacer/riser to the adapter cover using the eight capscrews, eight lock washers,
and eight flat washers provided with the spacer. Tighten all capscrews securely.
8. Using appropriate lifting equipment, hoist the cabinet several feet into the air to provide
access to the feeder and distribution cables.
9. Carefully route the stubbed feeder and distribution cables through the rectangular opening
in the ground spacer/riser or adapter cover and into the FMS.
Danger:
Do not stand directly under the cabinet as it is being hoisted into position for cable
installation. A failure of the lifting equipment could result in serious personal injury.
Note:
Label or tag the stub end of each cable so it can be identified after it is routed to the
splice enclosure.
21608-A