409-32048
Rev A
37
of 64
NOTE
Most of the controls on the IO Autoload tab require machine power for correct operation. The
Machine Enable
control on the
‘Safety’ tab should be activate
d before selecting the IO tab.
Basic manual Autoload functions are available on the IO Screen Autoload tab for use during part setup or to
allow clearing a conveyor jam. Refer to Setting Up Autoload.
NOTE
The notations on the IO Autoload tab are not reconfigured when the conveyor mode is changed. They always refer to the
conveyor working in its default direction, left-to-right. Ther
efore, the “Infeed” and “PCB at ” notations will appear logically
opposite when the conveyor mode is Reverse Production (right-to-left).
Figure 39
8.4.
Other Operating Functions
See Figure 39 for other operating functions.
1. The
Conveyor up SAV
and
Conveyor down SAV
buttons allow for manual raising and lowering of
the main Autoload conveyor rails. When both SAV (Solenoid Air Valve) buttons are off, both ports of
the lift air cylinders are closed to maintain position. The state of the four (4) conveyor lift air cylinder
sensors is indicated by the related input displays. The
Clamp PCB
button lowers and raises the two
main conveyor clamping bars that lock the PCB into position on the fixture. The state of the four (4)
clamping bar air cylinder sensors is indicated by the related input displays. The
Hard stop engage
SAV
button extends and retracts the main conveyor PCB hard stops that stop the PCB in position
directly above the fixture. The state of the two (2) hard stop air cylinder sensors is indicated by the
related input displays.
NOTE
This group of buttons is only active when the main co
nveyor Mode is set to ‘Manual’.
And it’s important to remember the
current Conveyor mode when switchi
ng from it to ‘Manual’ –
you will need to switch back!
I/O Screen
–
Autoload Tab
1
2
7
6
3
4
5
9
1
2
3
4
5
6
7
8
9