background image

408-1745

3

 of 7

Rev 

D

3. Insert the stripped wire into the wire barrel of 
terminal or splice. When crimping terminals and 
parallel splices, the end of the wire must be flush 
with or extend slightly beyond the end of the wire 

barrel. When crimping butt splices, wire must be 
visible through the inspection hole.Activate the 
power unit to complete the crimp.

Figure 5

Содержание 69069

Страница 1: ...uses the indenter and retains the terminal assembly for crimping a latch which allows pivoting of the yoke on the pivot pin typically required for splice terminations a cylinder which contains the hea...

Страница 2: ...p wires to the dimensions listed in Figure 3 CAUTION Do not use wires with nicked or missing conductor strands 6 CRIMPING PROCEDURE WIRE SIZE WIRE STRIP LENGTH Terminals Butt and Parallel Splices Min...

Страница 3: ...l or splice When crimping terminals and parallel splices the end of the wire must be flush with or extend slightly beyond the end of the wire barrel When crimping butt splices wire must be visible thr...

Страница 4: ...ect for cracks especially at the corners of the yoke and around the top of the cylinder 3 Inspect pivot pin holes and latch pin holes for wear Replace parts as needed 4 Activate power unit Raise ram t...

Страница 5: ...3 4 391 4 394 1729 1730 5 56 219 2 4 83 190 5 18 204 4 826 4 834 1900 1903 5 179 5 182 2039 2040 6 35 250 408 1745 5 of 7 Rev D Figure 7 Indenter in Full Up Position Plug Gage Detail A Detail B GO Gag...

Страница 6: ...r replaceable parts are listed in Figure 9 A complete inventory can be stocked and controlled to prevent lost time when replacement of parts is necessary Order replacement parts through your TE Repres...

Страница 7: ...04029 SPRING 1 15 3 21028 5 PIN Roll 094 Inches Dia X 438 Inches Long 1 19 1 21045 3 RING Retaining 2 21 2 21028 4 PIN Roll 078 Inches Dia X 812 Inches Long 1 22 21045 8 RING Retaining 4 23 301710 PIN...