■ Condition to meet Isolation & Withstand Voltage standard
Keep 4mm space from the top and surrounding of power supply. If the space is not enough, the specification of isolation
and withstand voltage will not be satisfied. Although, user should consider to keep space from the top and surrounding of
power supply for convection cooling.
/A, /TA and /L option model are not required to keep same spacing as the image to satisfy isolation and withstand voltage
specification. User should consider to keep space from the top and surrounding of power supply for convection cooling.
■
terminal
terminal should be connected to the protective earth terminal of the equipment. Also 4 mounting holes should be
connected to the Chassis (Conductor) by M3 metal screw or metal spacer. If they are not connected, the conducted noise,
radiation noise and output noise will increase.
More than
4mm
More than
4mm
More than 4mm
More than 4mm
More than 4mm
Protective Earth
Terminal
Wire
Chassis
(Conductor)
INPUT (CN1)
OUTPUT
(CN51,CN52)
Metal screw
Metal screw
Metal screw
Metal screw