17
CHAPTER 5:
PMBUS INTERFACE OPTION
5.1
RFE1600/S Series I
²
C Specification
1. FEATURES
1.1 Output voltage measurement
1.2 Output voltage programming.
1.3 Output current measurement
1.4 Internal ambient temperature measurement
1.5 Product information
1.6 Status information
1.7 SMBus alert
1.8 Clock frequency: 100KHz
1.9 Address lines: 4
2. OUTPUT VOLTAGE MEASUREMENT
RFE1600-12/S RFE1600-24/S RFE1600-32/S RFE1600-48/S
2.1 Measurement accuracy
-
+/-2% of full scale. Refer to instruction manual
2.2 Measurement resolution
-
10 bit
2.3 Measurement range (Full Scale, Only for Accuracy Calculation) V
0~15
0~30
0~40
0~60
3. OUTPUT VOLTAGE PROGRAMMING
RFE1600-12/S RFE1600-24/S RFE1600-32/S RFE1600-48/S
3.1 Programming accuracy
-
+/-2% of full scale
3.2 Programming resolution
-
10 bit
3.3 Programming range
V
9.6~13.2
19.2~29.0
25.6~38.4
38.4~58
4. CURRENT LIMIT PROGRAMMING
RFE1600-12/S RFE1600-24/S RFE1600-32/S RFE1600-48/S
4.1 Programming accuracy
-
+/-8% of full scale
4.2 Programming resolution
-
10 bit
4.3 Programming range
V
50~110% of full scale
5. OUTPUT CURRENT MEASUREMENT
RFE1600-12/S RFE1600-24/S RFE1600-32/S RFE1600-48/S
5.1 Measurement accuracy (*1)
-
+/-10% of full scale
5.2 Measurement resolution
-
10 bit
5.3 Measurement range (Full Scale, Only for Accuracy Calculation) A
0~160
0~80
0~60
0~40
(*1) Applicable for load above 15% of nominal output current
6. INTERNAL AMBIENT TEMPERATURE MEASUREMENT
6.1 Measurement device accuracy
-
±3°C
6.2 Measurement resolution
-
10 bit
6.3 Measurement range
℃
0~100
7. PRODUCT INFORMATION
7.1 Product ID
-
Factory programmed
7.2 Model Name
-
Factory programmed
7.3 Revision
-
Factory programmed
7.4 Serial Number
-
Factory programmed
7.5 Manufacturing location
-
Factory programmed
7.6 Coefficients
-
Factory programmed
7.7 Date of Manufacture
-
Factory programmed
7.8 Nominal Output
-
Factory programmed
8. STATUS INFORMATION
.
8 1 "FAN FAIL" Signal
-
"1" -FAIL, "0"-OK
8.2 "DC FAIL" Signal
-
"1" -FAIL, "0"-OK
8.3 Output "OVP" Signal
-
"1"- OVP, "0"-OK
8.4 "TEMPERATURE ALARM" signal
-
"1"- ALARM, "0"-OK
8.5 "OTP" Signal
-
"1" -OTP, "0"-OK
8.6 "AC FAIL" Signal
-
"1" -FAIL, "0"-OK
8.7 I²C ON/OFF control
-
"1" -ON, "0"-OFF
Содержание RFE1600 Series