14
3.2.8
Over Current Programming by External Voltage
Over Current Protection (OCP) can be programmed by external voltage source 0~5V. By changing the Current
Programming Voltage OCP level could be decreased down to ~40% of Nominal Output Current.
Figure 3–11:
Current Programming by Ext. Voltage
Figure 3–12:
Current Limit Programming
3.2.9
SUPERVISORY Signals (Typical Connection)
The following supervisory signals are accessible:
DC OK
AC FAIL
PS EXIST
TEMP ALARM
Figure 3–13:
Signals
SIGNAL RETURN and mentioned signals are isolated from the output terminals and -SENSE.
These signals are Open Collector type (max 15V, max 10mA) shunted by internal 24V Zener, isolated from Output and
referenced to “SIGNAL RETURN”.
Figure 3–14:
Open collector signals are shunted by internal 24V Zener
RFE1600
-SENSE J1-1
CURRENT PROG. J1-4
0~5V
+
120%
100%
80%
60%
40%
20%
0
0
2
5
3
Current Limit Programming
V PROG [V]
Icl / Irated
1
4
10k
Ω
10k
Ω
10k
Ω
RFE1600
DC OK J1-7
+12V AUX J1-18
AC FAIL J1-15
TEMP ALARM J1-6
SIGNAL RETURN J1-9