30kW Series Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° Celsius.
OUTPUT RATING
10-3000 20-1500 30-1020 40-750 50-600 60-510 80-390 100-300 150-204 200-150 300-102 400-78 500-60 600-51
1.Rated output voltage (*1)
V
10
20
30
40
50
60
80
100
150
200
300
400
500
600
2.Rated output current (*2)
A
3000(*3)
1500
1020
750
600
510
390
300
204
150
102
78
60
51
3.Rated output power
W
30000
30000
30600
30000
30000
30600
31200
30000
30600
30000
30600
31200
30000
30600
INPUT CHARACTERISTICS
V
10
20
30
40
50
60
80
100
150
200
300
400
500
600
1.Input voltage/freq. 3 phase, 3
wire+ground (*4)
--- 3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac).
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac).
2.Maximum
Input current at
100% load
3-Phase, 200V models:
--- 106.8A @ 200Vac.
3-Phase, 480V models:
56.2A @ 380Vac.
3.Power Factor (Typ.)
--- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (minimum) (*5)
%
87
88
89
90
CONSTANT VOLTAGE MODE
V
10
20
30
40
50
60
80
100
150
200
300
400
500
600
1.Max. Line regulation (*6)
--- 0.01% of rated output voltage.
2.Max. Load regulation (*7)
--- 0.01% of rated output v5mV.
3.Temperature coefficient
--- 50PPM/
O
C from rated output voltage, following 30 minutes warm-up.
4.Temperature stability
--- 0.01% of rated Vout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
5.Warm-up drift
--- Less than 0.05% of rated output v2mV over 30 minutes following power on.
6.Remote sense compensation/wire (*8) V
2
2
5
5
5
5
5
5
5
5
5
5
5
5
7.Up-prog. response time (*9)
mS
30
30
30
30
50
50
50
50
50
50
50
100
100
100
10.Down-prog.
response time
Full load (*9)
mS
50
50
80
80
80
80
100
100
100
100
100
150
200
200
No load (*10)
300
600
800
900
950
1000
1200
1900
2000
2500
3000
4000
4000
3000
11.Transient response time
---
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current.
Output set point: 10~100%, Local sense.
Less than 1mS for models up to and including 100V. 2mS for models above 100V.
CONSTANT CURRENT MODE
V
10
20
30
40
50
60
80
100
150
200
300
400
500
600
1.Max. Line regulation (*6)
--- 0.05% of rated output current.
2.Max. Load regulation (*11)
--- 0.08% of rated output current.
3.Temperature coefficient
---
10V~100V models: 100PPM/
O
C from rated output current, following 30 minutes warm-up.
150V~600V models: 70PPM/
O
C from rated output current, following 30 minutes warm-up.
4.Temperature stability
--- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
5.Warm-up drift
---
10V~100V models: Less than +/-0.25% of rated output current over 30 minutes following power on.
150V~600V models: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
--- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*12)
--- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming
---
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*12)
---
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor (*19)
--- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*12) (*19)
--- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1.Power supply OK #1 signal
--- Power supply output monitor. Open collector. Output On: On. Output Off: Off.
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
2.CV/CC signal
--- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V.
Maximum Sink Current: 10mA.
3.LOCAL/REMOTE Analog control
--- Enable/Disable analog programming control by electrical signal or dry contact.
Remote: 0~0.6V or short. Local: 2~30V or open.
4.LOCAL/REMOTE Analog signal
--- Analog programming control monitor signal. Open collector. Remote: On. Local: Off.
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
5.ENABLE/DISABLE signal
--- Enable/Disable PS output by electrical signal or dry contact.
0~0.6V or short, 2~30V or open. User selectable logic.
6.INTERLOCK (ILC) control
--- Enable/Disable PS output by electrical signal or dry contact.
Output ON: 0~0.6V or short. Output OFF: 2~30V or open.
7.Programmed signals
--- Two open drain programmable signals. Maximum voltage 25V. Maximum sink current 100mA
(shunted by 27V zener).
8.TRIGGER IN / TRIGGER OUT
signals
---
Maximum low level input voltage = 0.8V. Minimum high level input voltage = 2.5V.
Maximum high level input = 5V positive edge trigger: tw = 10us minimum. Tr,Tf = 1us maximum.
Min delay between 2 pulses 1ms.
9.DAISY_IN/SO control signal
--- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10.DAISY_OUT/PS_OK #2 signal
---
4~5V = OK, 0V (500Ω impedance) = Fail.
Содержание GBSPS10-3000
Страница 2: ...This page intentionally left blank ...
Страница 6: ...This page intentionally left blank ...
Страница 32: ...26 This page intentionally left blank ...
Страница 49: ...43 Power System Optional Earth Ground Connection ...
Страница 50: ...44 Power System Side View and Output Bus bars Dimensions All Dimensions are in mm ...