ATTENTION:

Risque de choc et de danger e'lectriques. Le de'branchement d'une seule alimenttation stabilise'e ne de'branche uniquement 

qu'un module "Alimentation Stabilise'e".

Pour isoler completement le module en cause, il faut de'brancher toutes les alimentations stabilise'es.

  SAFETY SYMBOLS

CAUTION   Risk of Electrical Shock.

Instruction manual symbol. The instrument will be marked with this symbol when it is 

necessary for the user to refer to the instruction manual.

Indicates hazardous voltage.

Indicates ground terminal.

Protective Ground Conductor Terminal

Denotes hazard. An attention to a procedure is called. Not following the procedure 

correctly could result in personal injury. A WARNING sign should not be skipped and 

all indicated conditions must be fully understood and met.

Denotes hazard. An attention to a procedure is called. Not following the procedure 

correctly could result in damage to the equipment.

  ENERGY HAZARD

The FPS1000 and FPS-TB products are capable of providing hazardous energy.

Manufacturers final equipment must provide protection to service personnel against inadvertent contact with these models 

output terminals.  If set such that hazardous energy can occur then the output terminals or connections therefore must not be 

user accessible.

  OVERCURRENT PROTECTION:

A readily accessible Listed branch circuit overcurrent protective device rated 20 A must be incorporated in the building wiring.

 FUSES

There are no user replaceable fuses in the FPS1000 and FPS-TB products. Internal fuses are sized for fault protection and if a 

fuse was opened it would indicate that  service is required. Fuse replacement should be made by qualified technical personnel.  

FPS-TB rack contains no fuses. FPS1000 units fuses rating are described below. 

F101: F20A H 250Vac

F102: 6.3A 400Vdc

 SICHERHEITSHINWEISE

Vor Anschluss an die Netzversorgung ist die Aufstellanleitung zu beachten!

1. Absicherung: F101: F20A H 250VAC, F102: 6.3A 400VDC

2. Der maximale Ableitstrom der Gesamtanlage darf 3.5mA nicht ueberschreiten.

3. Die Gehaeuseabdeckung darf nur im stromlosen Zustand geoeffnet werden.

ACHTUNG:

Sicherungen duerfen nur durch geschulte Service Personen getauscht werden. 

Содержание FPS-TB

Страница 1: ......

Страница 2: ......

Страница 3: ...FPS TB Outline Drawing...

Страница 4: ...dance with the preceding directives and standards has been made and is on file at our EU representative TDK LAMBDA UK located at Kingsley Avenue Ilfracombe Devon EX34 8ES UK A Declaration of Conformit...

Страница 5: ...ng hazardous energy Manufacturers final equipment must provide protection to service personnel against inadvertent contact with these models output terminals If set such that hazardous energy can occu...

Страница 6: ...FPS1000 TB Outline Drawing...

Страница 7: ......

Страница 8: ...ALS Signals are accessible at the J1 connector on the rear panel of the rack Fig 4 1 shows typical connection for FPS1000 inside the rack Refer to Table 1 Fig 3 1 Note AC_FAIL DC_OK and TEMP ALARM are...

Страница 9: ...ncreased output voltage It is recommended that diodes be connected in parallel with each unit output to prevent reverse voltage Each diode should be rated to at least the power supply rated output vol...

Страница 10: ...Note1 Forced air cooling allow minimum 50mm of unrestricted air space at the rear of the unit Do not obsruct air flow to the unit front panel ADDRESSING A0 A1 A2 The address line of the FPS1000 units...

Страница 11: ...80 5 of Vo rated Input voltage 85Vac The address of each FPS1000 unit is internally fixed Refer to the addressing table for details...

Страница 12: ...4 48 286V A D so that on every read data from each channel is read Note that on each read a conversion is started for a particular channel and the result which will be displayed and will be of the pre...

Отзывы: