  FPS1000 POWER SUPPLY AND FPS-TB SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Operating personnel must not remove the FPS1000 units and the FPS-TB rack cover.

No internal adjustment or component replacement is allowed by non Densei-Lambda qualified service personnel. Never replace 

components with power cable connected. To avoid injuries,always disconnect power, discharge circuits and remove external 

voltage sources before touching components. These products are not authorized for use as critical components in nuclear 

control systems, life support systems or equipment for use in hazardous environments without the express written approval of 

the managing director of Densei-Lambda.

Restricted Access Area: The equipment should only be installed in a Restricted Access Area. 

Access should be available to service personnel only.

WICHTIGE SICHERHEITSHINWEISE

Bedienungspersonal oder Anwender duerfen die Gehaeuseabdeckung  des FPS-1000 und des FPS-TB nicht entfernen.

Ersatzteiltausch - und Aenderungen duerfen nur von autorisiertem Densei-Lambda SERVICE-Personen bzw. Organisationen 

durchgefuehrt werden. Vor Austausch von Bauteilen ist das Netzkabel bzw. die Versorgungsspannung zu trennen.

Energieversorgungsanschluesse sind immer zu trennen, um Personenverletzungen durch gefaehrliche Energieinhalte und 

Spannungen auszuschliessen.

Die Stromkreise sind zu entladen, externe Spannungsquellen sind zu entfernen bevor Bauteile bzw. Komponenten getauscht werden.

Der direkte Zugriff auf das Racksystem ist nur dem geschulten Service-Personal erlaubt. 

SAFETY APPROVALS

UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada.

IEC 60950-1 - CB Report and Certificate.

EN 60950-1 - CE mark.

Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union.

A “Declaration of Conformity” in accordance with the preceding directives and standards has been made and is on file at our EU 

representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
A “Declaration of Conformity” may be accessed via company website www.uk.tdk-lambda.com/technical-data

SAFETY-CLASS OF INSULATION

The FPS1000 and FPS-TB are designed for the following safety parameters: Material group IIIa, Pollution degree 2, 

Overvoltage category II, Class I (earthed), indoor use as part of an overall equipment such that the FPS product is accessible to 

service personnel only.

GROUNDING

These products are Safety Class I instruments. To minimize shock hazard, the instruments chassis must be connected to an 

electrical ground. The instruments must be connected to the AC power supply mains through a three conductor power cable, 

with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet.

For instruments designed to be hard-wired to the supply mains, the protective earth terminal must be connected to the safety 

electrical ground before any other connection is made.

Any interruption of the protective ground conductor, or disconnection of the protective earth terminal will cause a potential shock 

hazard that might cause personal injury.

INPUT RATINGS

Do not use AC supply which exceeds the input voltage and frequency rating of these instruments. The input voltage and 

frequency rating is: 100-240V~ , 50/60Hz. For safety reasons, the mains supply voltage flactuations should not /-10% 

of nominal voltage.

The leakage current of the end use equipment should not exceed 3.5mA.

FPS-TB RACK AC INPUT

CAUTION:

  Risk of electrical shock and energy hazard. Disconnecting one power supply disconnects only one power supply  module.  

  To isolate the unit completely, disconnect all power supplies.

ACHTUNG:

  Spannungsfuehrende Teile - Gefahr durch elektrischen Schlag order hohe Energieinhalte.

  Alle Netzstecker der einzelnen Komponenten bzw. der Einschuebe muessen getrennt werden, damit das System  

 

  “spannungsfrei” ist.

Содержание FPS-TB

Страница 1: ......

Страница 2: ......

Страница 3: ...FPS TB Outline Drawing...

Страница 4: ...dance with the preceding directives and standards has been made and is on file at our EU representative TDK LAMBDA UK located at Kingsley Avenue Ilfracombe Devon EX34 8ES UK A Declaration of Conformit...

Страница 5: ...ng hazardous energy Manufacturers final equipment must provide protection to service personnel against inadvertent contact with these models output terminals If set such that hazardous energy can occu...

Страница 6: ...FPS1000 TB Outline Drawing...

Страница 7: ......

Страница 8: ...ALS Signals are accessible at the J1 connector on the rear panel of the rack Fig 4 1 shows typical connection for FPS1000 inside the rack Refer to Table 1 Fig 3 1 Note AC_FAIL DC_OK and TEMP ALARM are...

Страница 9: ...ncreased output voltage It is recommended that diodes be connected in parallel with each unit output to prevent reverse voltage Each diode should be rated to at least the power supply rated output vol...

Страница 10: ...Note1 Forced air cooling allow minimum 50mm of unrestricted air space at the rear of the unit Do not obsruct air flow to the unit front panel ADDRESSING A0 A1 A2 The address line of the FPS1000 units...

Страница 11: ...80 5 of Vo rated Input voltage 85Vac The address of each FPS1000 unit is internally fixed Refer to the addressing table for details...

Страница 12: ...4 48 286V A D so that on every read data from each channel is read Note that on each read a conversion is started for a particular channel and the result which will be displayed and will be of the pre...

Отзывы: