2. Part Number Indication
3. Explain of Terminal Connection
Take care of wiring this power supply. Incorrect wiring will damage this product.
3-1. Explanation of Terminal Connection
①
LED of Indicator (Refer to 9.User Interface section)
②
RESET : Tact Switch (Refer to 9.User Interface section)
③
ADDRESS : Rotary Switch (Refer to 9.User Interface section
)
④
Grid Connection Terminal
(
DC320V HVDC Terminal : M5 Screw
)
DC Power Supply Input Output Terminal -V
,
NC
※
2
, +V
(
The fuse is connected to +V)
⑤
CN : External Signal Connector (Refer to 10.System Interface section)
⑥
SW : DIP Switch (Refer to 9.User Interface section)
⑦
RS-485 : Serial Interface Connector (Refer to 10.System Interface section
)
⑧
Battery Connection Terminal
(
DC240V LVDC Terminal : M5 Screw
)
DC Power Supply Input Output Terminal -V
,
NC
※
2
, +V
(
The fuse is connected to +V)
⑨
Ground terminal (M5 Screw)
4/24
Optional Code
Rated Input / Output Voltage
Rated Output Power
Series Name
EZA 11K - 320240
※
1 Warning
When installing EZA11K, load the body on the chassis base side.
Don
’
t load of the body only by the side brackets for rack mount.
That would damage the bracket and chassis.
※
2 NC : There is no internal connection at this terminal.
④
⑤
⑥
⑦
⑧
⑨
①
②
③
※1 Bracket for Rack Maunt
※1 Bracket for Rack Maunt