background image

INSTRUCTION MANUAL

EZA11K Series

TDK-Lambda

<Page>

 

For  products  without  built-in  protection  circuit  (element,  fuse,  etc.),  insert  fuse  at  the  input  to  prevent  smoke,  fire  during  

abnormal operation.

 

 

As for products with built-in protection circuit, depending on usage conditions, built-in protection circuit might  not work. It 

is recommended to provide separate proper protection circuit.

 

For externally mounted fuse do not use other fuses aside  from our specified and recommended fuse.

 

This  product  was  made  for  general  purpose  electronic  equipment  for  standard  industrial  use  and  is  not  designed  for 

applications requiring high safety (such as extremely high reliability and safety requirements.  Even though high reliability 
and  safety  are  not  required,  this  product  should  not  be  used  directly  for  applications  that  have  serious  risk  for  life  and 
physical safety.  Take sufficient consideration in faile-safe design (such as providing protective circuit or protective device 
inside the system, providing redundant circuit to ensure no instability when single device failure occurs).

 

When used in environments with strong electromagnetic field, there is possibility of product damage due to malfunction.

 

When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.) , there is possibility that they might 

penetrate the product and lead to failure.

 

When  used  in  environments  where  there  is  conductive  foreign  matter  or  dust,  there  is  possibility  of  product  failure  or 

malfunction.

 

Provide countermeasure for  prevention of lightning surge voltage as there is risk of damage due to abnormal voltage.

 

Connect together the frame ground terminal of the product and the ground terminal of the equipment  for safety and noise 

reduction. If these ground is not connected together, there is risk of electric shock.

 

Parts with lifetime specifications (built-in fan, electrolytic capacitor) are required to be replaced periodically. 

 

 

Set the overhaul period depending on the environment of usage and perform maintenance. 

 

 

Also, note that there are cases when EOL products cannot be overhauled. 

 

Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or overvoltage more 

than the rated voltage to the output might cause failure, electric shock or fire.

 

Do  not  use  in  special  environment  such  as  places  directly  exposed  to  sunlight,  dew  condensation,  moisture,    rain,  strong 

electro-magnetic field, or corrosive gas (hydrogen sulfide, sulfur dioxide).  

 

This product have a built-in fan for air-cooling. Do not block the air intake and exhaust.

 

On the occasion of obtain of Safety Standard, this power supply is not considered for connect bV terminal and 

earth.

 

The output of this product is considered to be a hazardous energy level (The voltage is 2V or more and the power is 240VA 

or more). It must not be made accessible to users. Protection must be provided for Service Engineers against indirect contact 
with the output terminals and/or to prevent tools being dropped across them. While working on this product, the DC input 
power must be switched off and the input and output voltage should be zero.

 

When short the output  during operation, there is a damage inside the converter.

 

When change abrupt  in Input voltage during operation, there is a Risk of damage inside the converter. 

 

When  use  the  Electric  storage  device,  Please  refer  to  the  manual  of  e lectric  storage  device  and  use  the  appropriate 

protection device.

Note

 

There is a possibility machining traces remain on sheet metal of product.

 

Consider  storage  of  the  product  at  normal  temperature  and  humidity  avoiding  direct  exposure  to  sunlight  at  environment 

with minimal temperature and humidity changes. Storage of product at high temperature, high humidity and  environments 
with severe changes in temperature and humidity might cause deterioration, and occurrence of condensation in the product.

 

When disposing product, follow disposal laws of each municipality.

 

Published EMI (CE, RE) or immunity is the result when measured in our standard measurement conditions and might not 

satisfy specification when mounted and wired inside end-user equipment.

 

 

Use the product after sufficiently evaluating at actual end-user equipment.

 

Catalogue,  contents  of  the  instruction  manual  may  be  changed  without  a  prior  notice.  Refer  to  latest  catalogue  or  

instruction manual.

 

Reproduction or reprinting the instruction manual or its portion is forbidden without our permission.

2/24

Содержание EZA11K Series

Страница 1: ...not attempt repair by yourself as it is dangerous for the user Do not operate and store these products in environments where condensation occurs due to moisture and humidity It might lead fire and ele...

Страница 2: ...ltage to the output Especially applying reverse voltage or overvoltage more than the rated voltage to the output might cause failure electric shock or fire Do not use in special environment such as pl...

Страница 3: ...sitive at generation and negative at regeneration Note When attach the battery or large capacitance capacitor please use the line over 1 5M to connect the device to the converter terminal Bi direction...

Страница 4: ...N External Signal Connector Refer to 10 System Interface section SW DIP Switch Refer to 9 User Interface section RS 485 Serial Interface Connector Refer to 10 System Interface section Battery Connecti...

Страница 5: ...ections for input output and connector terminals Route input line and output line separately to avoid noise interference Connect protective earth grounding to the terminal of this power supply Use the...

Страница 6: ...r the initialize process the converter will be in waiting mode Power conversion operation will start when the operation command is sent The internal FANs are rotated during any power conversion operat...

Страница 7: ...s when battery voltage level reaches the target voltage level Refer to 7 Battery Protection Grid bus ramp up mode can be selected for charged up capacitor Max 15000 F of grid side from 0V and or for o...

Страница 8: ...e and over discharge protection that stops charging and discharging process when battery voltage level reaches the target voltage level Refer to 7 Battery Protection Grid bus ramp up mode can be selec...

Страница 9: ...e The converter is necessary the pre charged voltage at battery side and grid side See illustration below The converter cannot startup when the pre charged voltage is not enough 9 24 Generation Charge...

Страница 10: ...The rotary switch functions as the RS 485 address setting for this converter The interface address is composed of 7 bits and can be set within the range 0x00 0x7E range Rotary switch is used to set th...

Страница 11: ...al PG is outputted Pin 3 becomes short to SG during Converter Operation Power Conversion 10 1 3 Converter Operation Stop Command STOP By shorting this signal to SG the converter can be forcibly stoppe...

Страница 12: ...ut 2ms typ Chattering removal time 16ms No Voltage Contact Input When use semiconductor SW ON voltage should be 0 3V maximum Converter can be forcibly stopped by pin 5 short to SG Converter shuts down...

Страница 13: ...termediate RS 485 connectors Due to this feature RS 485 bus can be extended simply by connecting interface cables between converters when connecting multiple converters to the host devices Depending o...

Страница 14: ...Alert is detected external signal connector ALM signal is triggered open When this happens during power conversion process power conversion stops and the external signal connector PG becomes open Heav...

Страница 15: ...verter Stop Command External Signal When Converter Stop Command of the External Signal Connector is detected the Converter Stop Alarm is triggered 11 2 9 Fan Lock If internal FAN rotation speed reduce...

Страница 16: ...r Voltage Alarm is triggered Detect threshold level is fixed 11 2 14 System Alert When Abnormality is detected in this converter System Alarm will be triggered Alarm due to System Alert is not covered...

Страница 17: ...ollow below indications 1 Please set same output voltage 2 Please use same size and same length of output wires 3 Please use same size and same length of input wire for each separate converter 12 8 Dy...

Страница 18: ...voltage must be gradually increased from zero to testing value and then gradually decreased to zero When timer is used the unit may be damaged by high rate of change of voltage at turn on off Ramp the...

Страница 19: ...1min 50mA Must connect short all pins of RS 485 and CN Notes This product has ceramic capacitor between primary circuit and chassis and between secondary circuit and chassis Some withstand voltage tes...

Страница 20: ...6mm Converter Side View 20 24 Warning When installing EZA11K load the body on the chassis base side Don t load of the body only by the side brackets for rack mount That would damage the bracket and c...

Страница 21: ...ng type converter This converter has ventilating holes on the front and rear side panel Keep these two areas freely as much as possible 2 The maximum allowable penetration of mounting screws is 6mm In...

Страница 22: ...ltage V HVDC Voltage V Output Voltage V Output Current A Output Current A Output Voltage V Output Current A Output Current A 14 Output Derating 14 1 LVDC Voltage vs LVDC Current Derating 14 2 HVDC Vol...

Страница 23: ...ousing 2 Insert contact into housing without stopping to its furthest extent 3 Check secure locking on each insertion by pulling wire softly in order to check that contact does not come off housing Be...

Страница 24: ...ssis of converter abnormally hot The output might shut down by OTP operation Please re start after allowing time for the unit to cool down sufficiently 7 Check if the output current and output wattage...

Отзывы: