68. Redundant Operation
Redundant operation is possible for loads that are within the maximum output power of one power
supply. When one power supply is shutdown by the power failure etc., another one can continue to
provide power.
69. Parallel Operation
Parallel operation cannot be used.
610. Series Operation
Series operation is possible for CCG series.
Connections shown in Fig.69 and Fig.610 are possible.
Fig.67 Redundant Operation Connection (CCGS)
Fig.69 Series Operation for High Output Voltage
+Vout
Vout
CCG
+Vout
Vout
CCG
+
Load
+
Load
+Vout
Vout
CCG
+Vout
Vout
+
Load
CCG
Fig.610 ±Output Series Operation
+Vout
Vout
CCGD
+Vout
Vout
CCGD
+
LOAD
GND
COM
COM
Fig.68 Redundant Operation Connection (CCGD)
<
Reference
>
CCGD can be used as 24V or 30V single output by conn Vout and Vout to the load.