INSTRUCTION MANUAL
CCG
TDKLambda
<Page>
6/23
5. Terminal Connecting Method
In order to use the CCG series, this power supply must be connected with external components
according to Fig.51.
If it is connected to wrong terminal, the power supply will be damaged. Pay attention to each wiring.
Fig.51 Basic connection
F1 : Input Fuse
CCG series has no internal fuse.
Use external fuse to comply various Safety Standards and to improve safety.
Moreover, use fastblow type for every power supply.
Furthermore, fuse must be connected to +Vin side if Vin side is used as ground, or fuse must be
connected to Vin side if +Vin side is used as ground.
Consider margin over the actual input voltage to be used when selecting fuse. Moreover, consider
I
2
t fuse rating for surge current (inrush current) during line throwin.
Input Fuse Recommended Current Rating
CCG1524xxS/D : 6.3A or lower
CCG1548xxS/D : 5.0A or lower
CCG3024xxS/D : 10A or lower
CCG3048xxS/D : 6.3A or lower
CCGS
+Vin
RC
+Vout
Vout
C1
Vin
Load
TRM
F1
+
Vin
CCGD
+Vin
RC
+Vout
Vout
C1
Vin
Load
COM
F1
+
Vin
Load
+
CCGS
+Vin
RC
+Vout
Vout
C1
Vin
Load
TRM
F1
+
Vin
CCGD
+Vin
RC
+Vout
Vout
C1
Vin
Load
COM
F1
+
Vin
Load
+
(a) Standard model (Negative Logic model)
(b) Positive Logic model