122
Name
Description
Min Max Default
UM
Scale
SENSOR_FRQ_IN
D39 - Input frequency
0
kHz
16
REG_CARD_TEMP
D40 - Regulation card temperature
0
°C
16
MOT_PRB_RES
D41 - Thermal probe resistance
0
Ohm
1
AI1
D42 - Analog Input AI1
-100 100
0
%
163.84
AI2
D43 - Analog Input AI2
-100 100
0
%
163.84
AI3
D44 - Analog Input AI3
-100 100
0
%
163.84
SPD_ISR
D45 - Speed routine duration
0
us
64
I_ISR
D46 - Current routine duration
0
us
64
I_LOOP_BAND
D47 - Current loop bandwidth
0
Hz
1
PRC_APP_T_MIN
D48 - Minimum torque limit by application
-100 100
0
% MOT_T_NOM
40.96
WORK_HOURS
D49 - Work Hours
0 hours 1
SENS2_SPD
D51 - Second sensor rotation speed
0
rpm
1
SENS2_TURN_POS
D52 - Second sensor Absolute mechanical position
(on current revolution)
0 16384 1
SENS2_N_TURN
D53 - Second sensor Number of revolutions
0
16384
1
SENS2_FRQ_IN
D54 - Second sensor Frequency input
0
KHz
16
SENS1_ZERO_TOP
D55 - Sensor1 Zero Top
0
pulses
1
SENS2_ZERO_TOP
D56 - Sensor2 Zero Top
0
pulses
1
SYNC_DELAY
D57 - Delay from SYNC reception to Speed routine
execution
0 us 1
PWM_SYNC_OFFSET
D58 - PWM offset for SYNC delay control
0
pulses
1
SERIAL_NUMBER
D59 - Drive Serial Number
0
1
FLD_CARD
D60 - Fieldbus Card
0
1
APPL_REV
D61 - Application Revision
0
40.96
HW_SENSOR2
D62 - Sensor2 presence
0
1
HW_SENSOR1
D63 - Sensor1 presence
0
1
REF_AI1
D64 - Reference from Analog Input AI1
-100 100
0
%
163.84
REF_AI2
D65 - Reference from Analog Input AI2
-100 100
0
%
163.84
REF_AI3
D66 - Reference from Analog Input AI3
-100 100
0
%
163.84
PRC_SPD_REF_DG_POT D67 - Digital Potentiometer Speed reference
-100 100
0
% MOT_SPD_MAX 163.84
PRC_T_REF_AN
D68 - Analog Torque reference from Application
-400 400
0
% MOT_T_NOM
40.96
PRC_T_REF_FLDBUS
D69 - Fieldbus Torque reference
-400 400
0
% MOT_T_NOM
40.96
PRC_T_MAX_AN_POS
D70 - Analog Positive Torque Max from Application
-400 400
0
% MOT_T_NOM
40.96
PRC_T_MAX_FLDBUS
D71 - Fieldbus Torque Max reference
-400 400
0
% MOT_T_NOM
40.96
PRC_SPD_TOT_AN
D72 - Speed reference from AI1 + AI2 + AI3
-100 100
0
% MOT_SPD_MAX 163.84
MUL_KP
D73 - Multiplication factor
-
100.0
100.0 0
%
16
PRC_SPD_REF_AN
D74 - Speed reference
-100 100
0
% MOT_SPD_MAX 163.84
PRC_SPD_REF_FLDBUS D75 - Fieldbus Speed reference
-100 100
0
% MOT_SPD_MAX 163.84
PRC_SPD_REF_JOG
D76 - Jog Speed reference
-100 100
0
% MOT_SPD_MAX 163.84
PRC_SPD_REF_TIME_DEC
D77 - Time Decode Frequency input Speed
reference
-100 100 0 %
MOT_SPD_MAX 163.84
SPD_REF_PULS_FLDBUS D78 - Fieldbus Speed Reference in Pulses
0
Pulses per Tpwm
1
REF_AI16
d79 Reference from analog Input AI16
%
163.84
PRC_T_MAX_AN_NEG
D80 - Analog Negative Torque Max from Application -400 400
0
% MOT_T_NOM
40.96
ACT_SP_PID
d85 Actual Setpoint PID
%
163.84
ACT_PV_PID
d86 Actual Feed-back PID
%
163.84
ACT_COM_P_PID
d87 Actual Componente P of PID
%
163.84
ACT_COM_I_PID
d88 Actual Componente I of PID
%
163.84
ACT_COM_D_PID
d89 Actual Componente D of PID
%
163.84
ACT_ERR_PID
d90 Actual Errore SP-PV of PID
%
163.84
ACT_OUT_PID
d91 Actual Output PID
%
163.84
Содержание MINIOPD EXP