118
Name
Description
Min
Max Default
UM
Scale
DEAD_TIME_HW
P198 - Dead time hardware duration
0.0
20.0
0.0
µs
10
MIN_PULSE
P199 - Minumum command pulse duration
0.0
20.0
1.0
µs
10
EN_AI1
P200 - Enable analog reference value A.I.1
0
1
0
1
EN_AI2
P201 - Enable analog reference value A.I.2
0
1
0
1
EN_AI3
P202 - Enable analog reference value A.I.3
0
1
0
1
AI1_SEL
P203 - Meaning of analog input A.I.1
0
4
0
1
AI2_SEL
P204 - Meaning of analog input A.I.2
0
4
1
1
AI3_SEL
P205 - Meaning of analog input A.I.3
0
4
2
1
TF_TRQ_REF_AN
P206 - Filter time constant for analog torque
reference value
0.0 20.0
0
ms
10
EN_AI16
P207 - Enable analog reference value A.I.16
0
1
0
1
AI16_SEL
P208 - Meaning of analog input A.I.16
0
4
0
1
PRC_SPD_JOG
P211 - Digital speed reference value (JOG1) -100.00
100.0
0
0 %
MOT_SPD_MAX
163.84
EN_SPD_JOG
P212 - Enable jog speed reference
0
1
0
1
PRC_START_DG_POT
P213 - Motor potentiometer starting speed
-100.0 100.0
2.00
% MOT_SPD_MAX 163.84
EN_MEM_DG_POT
P214 - Load final digital potentiometer
reference value
0 1 0
1
PRC_MAX_REF_DG_POT
P215 - CW motor potentiometer speed
reference value
-105.0 105.0 105.02 %
MOT_SPD_MAX 163.84
PRC_MIN_REF_DG_POT
P216 - CCW motor potentiometer speed
reference value
-105.0 105.0 -105.02 %
MOT_SPD_MAX 163.84
DG_POT_RAMPS
P217 - Digital potentiometer acceleration
time
0.3
1999.
9
50 s 10
EN_DG_POT
P218 - Enable motor potentiometer
reference value(A.I.4)
0 1 0
1
TIME_DEC_FRQ_SEL
P219 - Meaning of frequency speed
reference value decoded in time
0 3 0
1
FRQ_IN_PPR_SEL
P220 - Encoder pulses per revolution
0
9
5
1
FRQ_IN_NUM
P221 - NUM - Frequency input slip ratio
-16383 16383
100
1
FRQ_IN_DEN
P222 - DEN - Frequency input slip ratio
0
16383
100
1
EN_FRQ_REF
P223 - Enable frequency speed reference
value
0 1 0
1
FRQ_REF_SEL
P224 - Frequency speed reference selection
0
2
0
1
TF_TIME_DEC_FRQ
P225 - Filter time constant of frequency
input decoded in time
0.0 20.0
1.6
ms
10
KP_TIME_DEC_FRQ
P226 - Corrective factor for frequency input
decoded in time
0.0 200.0
100
163.84
SB_MOT_SPD_MAX
P227 - Second bank Max. operating speed
50
30000 3000
rpm
1
SB_SPD_REG_KP
P228 - Second bank KpV speed regulator
proportional gain
0.1 400.0
6
10
SB_SPD_REG_TI
P229 - Second bank TiV speed regulator
lead time constant
0.1
3000.
0
30 ms 10
SB_SPD_REG_TF
P230 - Second bank TfV speed regulator
(filter) time constant
0.0 25.0
0.4
ms
10
SB_CW_ACC_TIME
P231 - Second bank CW acceleration time
0.01
199.9
9
10 s 100
SB_CW_DEC_TIME
P232 - Second bank CW deceleration time
0.01
199.9
9
10 s 100
SB_CCW_ACC_TIME
P233 - Second bank CCW acceleration time
0.01
199.9
9
10 s 100
SB_CCW_DEC_TIME
P234 - Second bank CCW deceleration time
0.01
199.9
9
10 s 100
SB_ON
P235 - Second bank active
0
1
0
1
EN_LIN_RAMP
P236 - Enable linear ramp
0
1
0
1
EN_INV_SPD_REF
P237 - Invert reference signal software
0
1
0
1
EN_I_CNTRL
P238 - Enable only current control
0
1
0
1
EN_POS_REG
P239 - Enable overlapped space loop
0
1
0
1
EN_POS_REG_MEM_CLR
P240 - Enable overlapped space loop
memory clear in stop
0 1 0
1
MUL_AI_IN_SEL
P241 - Multiplication factor selection
0
4
0
1
MUL_AI_OUT_SEL
P242 - Multiplication factor target
0
2
0
1
MUL_AI_MAX
P243 - Max analog input value for
multiplication factor
-180.00
180.0
0
100.0 %
A.I. 163.84
MUL_AI_MIN
P244 - Min analog input value for
multiplication factor
-180.00
180.0
0
0.0 %
A.I.
163.84
MUL_KCF_MAX
P245 - Multiplication factor with max analog
input (MUL_AI_MAX)
-100.0 100.0
1.0
100
MUL_KCF_MIN
P246 - Multiplication factor with min analog
input (MUL_AI_MAX)
-100.0 100.0
-1.0
100