background image

 

01/2013 

TCS TürControlSysteme AG, TCS Hotline Germany:  +49 (0) 41 94/ 9 88 11 88

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129  

  Mail: [email protected]

 

PI_K30001-30004_uk  1A 

 

Optinal modules 

 

 

 
Optionally, further modules (in total 6) can be installed in the communication posts K3000x. 
For information on the optional modules see the enclosed product information 

Modules of the series AMI 

in front-door stations.

 

 
 

Intended use 

 

  Types 

K30001: post audio display jogwheel 100 flats,  
K30002: post video display jogwheel 100 flats,  
K30003: post audio display keypad 100 flats,  
K30004: post video display keypad 100 flats. 

  The communication posts K30001-K30004 are front-door stations constructed as posts, 

stand-alone with display module. They can be individually extended with functional 
modules 

according to customer’s specifications.  

  The posts are suitable for vertical installation outdoors and need to be installed on flat, 

massive grounds (e.g. concrete). 

  The communication posts and modules are permitted exclusively for safety extra low 

voltages (SELV) and protective extra low voltage (PELV). 

 

!

 

Attention when using the display module! 
Avoid direct solar radiation (ambient temperature of max. 50 °C)! 
Direct solar radiation (UV component) reduces the durability of the liquid crystals 
within the display. 

 

Warning! 

The operating elements of the modules can become very hot when under direct solar radi-
ation (more than 50 °C). When selecting the mounting site, please observe to avoid direct 
solar radiation on the installation location. 
 
 

Short description 

Display modules LCD graphic AMI1010x-0000 

Display modules for front-door stations in individualised assembly 

  for up to 100 flats (optionally 200 or 1000 flats) 

  graphic LC display, 160 x 160 points with white backlight 

  jogwheel or keypad module necessary to select the name for the call destination  

  codelock function (number of codes: 3) 

  call destination selection via an alphabetical sorted resident list or by entering the target 

number (flat number) as quick selection 

  adjustable (rotation)direction in the name list, name list is endless as of 6 datasets 

  name pre-selection can be realised via the initial letter 

  start screen can be configured by a qualified electrician 

Содержание K30001

Страница 1: ...olSysteme AG TCS Hotline Deutschland 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_K30001 30004_uk 1A Product information Communication posts K300...

Страница 2: ...en and install the post 11 Note 12 Wiring diagram 12 Connection diagram K30001 K30003 13 Connection diagram K30002 K30004 13 Close the post 13 Commissioning 13 Note for connecting more than front door...

Страница 3: ...evice 4 x heavy duty anchor W SAi M10 4 x cylinder screw with hexagon shape DIN 912 M10 x75 to fix the post 1 x clamp for strain relief only a pluggable part 1 x key for hexagon socket screws DIN 911...

Страница 4: ...onduit of heavy and low current lines minimum distance of 10 cm in case of a common conduit use of separators between heavy and low current lines within shared cable ducts use of standard communicatio...

Страница 5: ...Return to the first letter drop down menu Confirming the selected letter When in start screen pressing the ABC button leads to help menu Browse in the resident list or in the menu Pressing the button...

Страница 6: ...ively for safety extra low voltages SELV and protective extra low voltage PELV Attention when using the display module Avoid direct solar radiation ambient temperature of max 50 C Direct solar radiati...

Страница 7: ...line 2 m R terminal to connect an extended function door release door release time at R terminal ex works 3 seconds can be adjusted with PC keypad or ADx configurator door release when in door standb...

Страница 8: ...data supply voltage 24 V 8 power supply and control unit housing front panel modules aluminium profile power coated grey aluminium anodised nature aluminium anodised black resp plastics dimension in...

Страница 9: ...300 0057 housing aluminium anodised black dimensions in mm H 105 x W 105 x D 15 weight 130 g Jogwheel module AMI10400 0057 housing aluminium anodised black dimensions in mm H 105 x W 105 x D 52 weight...

Страница 10: ...tall the camera module on sites where it is directly exposed to rain Water droplets on the dome or the viewing window can impair the image quality Do not install and operate the camera module on sites...

Страница 11: ...6 Push the lower back panel upwards until a small grub screw can be seen above the oval hole Secure this back panel Turn out the grub screw with a small screwdriver until the back panel cannot slipe...

Страница 12: ...1 94 9 88 129 Mail hotline tcsag de PI_K30001 30004_uk 1A Note All modules are permitted exclusively for safety extra low voltage SELV and protec tive extra low voltage PELV Wiring diagram FBS2100 Tem...

Страница 13: ...urled screws 2 Insert the upper back panel and push it downwards until it is flush with lower back panel Fis the back panel with both knurled screws 3 Fix the roof of the post with the 4 screws It is...

Страница 14: ...h modules Setting the AS address in the PES is only possible with the Service Device TCSK 01 or the configuration software configo TM Setting the AS address of a front door station with AMI modules is...

Страница 15: ...eat pressing the F12 button on the PC keypad until the required contrast is adjusted The font appears darker ex works middle position Set the volume This function can only be used when a voice connect...

Страница 16: ...1A 17 19 15 6 C Adler Apotheke Arnold Baumgarten E Dombrowski Alf Frey OK Hilfe Rufen Establish a voice connection between the display front door station and an indoor station Press the F5 button on...

Страница 17: ...e selection by pressing the ABC button The first resident with the selected initial letter is dis played Browse Turn the jogwheel until the re quired name with the selected ini tial letter appears Bro...

Страница 18: ...ent list Turn the jogwheel carefully The help menu appears or Browse Turn the jogwheel until the re quired name is marked 17 19 15 6 C Adler Apotheke Arnold Baumgarten E Dombrowski Alf Frey Rufen Call...

Страница 19: ...s the ABC button or another button but not C or number The help menu appears Press the ABC button Browse Press the UP or DOWN button or keep it pressed until the re quired initial letter appears Confi...

Страница 20: ...the following note appears by selecting in the resident list Start name selection mode Browse through the resident list Press the UP or DOWN button twice The resident list appears Browse Press the UP...

Страница 21: ...confirmed The following display appears and a door call is signaled at the front door station If the telephone does not respond resp the front door station does not acknowledge the following note appe...

Страница 22: ...by all authorised persons Enter the access code Correct entry Unknown access code The input menu can only be called up from the start screen Press the C button The following display appears Enter the...

Страница 23: ...ines are used illustra tion The lines must be twisted When using shielded lines connect the shields with each other and connect one side to ground b wire at the power supply Optional star or strand sh...

Страница 24: ...a b polarity free only in 6 wire operation Thus a suitable power supply and control unit is to be used Table 1 loop resistances Length of the line a b M P in m Line diameter 0 6 mm 0 8 mm Loop resist...

Страница 25: ...t on the module with sealing 3 Fix the module with 4 self locking nuts enclosed in the delivery Display module AMI1010x 0000 Replace the EEPROM storage Changes in datasets and parameter are not stored...

Страница 26: ...age to transfer the data into the electronic module Cleaning Avoid water from entering the device Do not use any abrasive detergents Clean the device with a dry or slightly wet cloth Remove stronger s...

Страница 27: ...hotline tcsag de PI_K30001 30004_uk 1A Warranty We offer a simplified processing in case of warranty for electricians Please note our conditions of sale and delivery download from www tcsag de down l...

Страница 28: ...l changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_K30001 30004_uk 1A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Sch...

Отзывы: