Safety instructions
General safety regulations
!
Attention! Mounting, installation, commissioning and repair of electronic devices have
to be carried out only by qualified electricians. Thus, the standards and instructions for
the installation of systems have to be observed.
For working on systems with main connection of 230 V alternating voltage, the safety re-
quirements according to DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated conduit of heavy and low current lines,
minimum distance of 10 cm in case of a common conduit,
use of separators between heavy and low current lines within shared cable ducts,
use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross-sections can be used in compliance
with the loop resistance.
Installation
– protective meaures
!
With suitable measures to protect against lightning, it has to be ensured that a voltage
of each 32 V DC is not exceeded at the connections a, b, P, R, S (V1, V2).
!
The communication posts and modules are permitted exclusively for safety extra low
voltage (SELV) and protective extra low voltage (PELV).
Overview of the modules
Functional group with
display module
operating elements
Display module AMI1010x-00000
AMI10100-0000 display module LCD graphic, 100 flats
AMI10103-0000 display module LCD graphic, 200 flats
AMI10105-0000 display module LCD graphic, 1000 flats