14
01/2013
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
Mail: [email protected]
PI_K30001-30004_uk 1A
Notes to connect more than one front-door station
In a system with a voltage supply, realised by a single NGV1011, max. 5 front-door sta-
tions (or communication posts) with AMI modules can be connected.
If a front-door station with AMI modules is operated parallel to other front-door stations
with AMI modules or front-door stations of the series PES, the AS-addresses of these
stations have to be set fix. Usually, the PES stations agree among themselves automat-
ically regarding their AS-addresses. This mechanism does not work in combination with
a front-door station with modules.
Setting the AS-address in the PES, is only possible with the Service Device TCSK-01 or
the configuration software configo
TM
.
Setting the AS-address of a front-door station with AMI modules is realised with the PC
keypad via the menu navigation (see programming manual
Functional group with dis-
play modules AMI1010x
), with the Service Device TCSK-01 or the software ADx config-
urator.
Device start-up
Device start-up
After switching ON the device, the system
screen appears for around 5 sec.
The resident list appears.
30 sec after switching ON the device, the
start screen appears.
(delivery state: TCS-Logo)
The device is in standby mode.
Start screen on customers request
A different start screen can be set or a differ-
ent image can be loaded (see programming
manual
Modules in front-door stations
). The
image has to be uploaded into the memory of
the front-door station via the software ADx
configurator.
Examples for the start screen
AMI10100