14
07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
Mail: [email protected]
ISW3030-0140 UK 2 A
Repair
Error detection and indication
Errors will be indicated optical and acoustic: error tone for one time and constant flashing
of the operation indication. When pressing any button, the error tone sounds again. The
optical error indication stays active until the error is resolved.
error causes
display
error
mode
error tone elimintaion
a- and P-wire interchanged
or short-circuited
both
LEDs
are
flashing
change a- and P-wire or eliminate short-circuit,
device is going into sleep mode again
a-wire: not connected or
not supplied
connect the a-wire or proof power supply,
device is going into sleep mode again
Button stucks
(press longer than 15 sec)
remove button at the device or floor push button,
device is going into sleep mode again
Exchange of an indoor station
– programming bell buttons
Basic principle
All devices at the TCS:BUS have got an unique serial number.
Programming a bell button means that the serial number of an indoor station is allocat-
ed to the bell button of a front-door station and is stored within the EEPROM of the
front-door station.
Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage
is switched on (the operation LED at the power supply and control unit is ON) and fur-
ther, that the access to the flat is granted during the programming.
This instruction describes the case that a serial number is allocated to a bell button and
no programming lock is set. To deactivate a programming lock you need a Service De-
vice TCSK-01or the configuration software confi
go™.
1
Initiate
power supply and control unit
press shortly
LED blinks
Programming mode of the system is ON