682 METER EXCHANGE PROGRAM 

 

 
 
Overview 
 
TCS offers an exchange program on the 682 AF and SP meters.  The exchange price, equa l to 
less than 1/3 the price of a new meter, after the credit given from the returned meter core.  This 
makes the exchange program a powerful value - added option for 682 owners.  Exchange meters 
are available for same day shipping.  For the exchange program to continue smoothly, the used 
meter must be returned to TCS as promptly as possible, especially in the spring months. 
 
Exchange Program Highlights 
 
1)  Exchange meters are always in stock. 
2)  Fast service to your customer minimizes downtime. 
3)  Customer needs fe wer parts for inventory to ensure continuous operation. 
4)  All exchange meters maintain NTEP Certificate of Conformance. 
5)  The program applies to one meter or several meters at a time. 
6)  Meters are factory tested and calibrated. 
7)  Saves your customer money. 
8)  Repeat business for distributor. 
9)  Meter can be rebuilt numerous times. 
 
Program Details 
 
When a meter is exchanged, the user retains his register and adapter, as well as any other 
accessories he may have (presets, ticket printers, etc.).  Separate exchange programs exist for 
registers and some other accessories. 
The exchange meter, which is shipped from TCS, is calibrated and freshly painted.  The 
exchange meter is guaranteed to be free of defects in material and workmanship for 180 days 
from the date it ships to the end user or distributor. 
The used meter returned to TCS should be shipped freight prepaid (truck shipments are 
recommended for the safety of meter).  

It must be flushed and have a Material Safety Data 

Sheet (MSDS) identifying the product that was in the meter.  

Regardless of the condition of the 

internal parts of the meter, the only additional charge a distributor may be subject to is for the 
upper or lower housing.  If the upper or lower housing is chipped, cracked, welded or similarly 
damaged and in ne ed of replacement, then the dealer's core credit will be reduced accordingly. 

Содержание 682-15

Страница 1: ...CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com The Standard of Measurement 682 15 Piston Flow Meter SERVICE...

Страница 2: ...s Alcohols Adhesives Motor Oils Molasses Corn Syrup Liquid Sugars Deicing Fluids etc SS Stainless Steel For metering all the same liquids as the SP and AF flow meters however includes special handling...

Страница 3: ...uct enters the meter it initially flows into the upper housing The sliding valve will now be in position to open one measuring cylinder The plunger for that particular cylinder will be at the upper po...

Страница 4: ...40 to 50 percent of flow Operating Temperature The temperature range of the product to be metered must be within the meter s range The SP meter can operate between 20 F and 200 F The AF and SS meters...

Страница 5: ...tire system Protection From Debris On new installations care must be taken to protect the meter from damage during start up Damage may result from the passage through the meter of welding slag or spat...

Страница 6: ...differ beyond the rated tolerance of the meter then repairs are necessary before the meter can be calibrated B A valve or nozzle must be at the end of the delivery hose at the prover C Turn on the pu...

Страница 7: ...0 5 10 15 20 0 5 10 15 20 25 30 35 40 GALLONS PER MINUTE P S I The 682 meter is mechanically capable of accurately metering products as slow as 0 2 GPM and as quick as 40 GPM Comparing the lowest and...

Страница 8: ...VISCOUS LIQUIDS PERFORMANCE...

Страница 9: ...epeat business for distributor 9 Meter can be rebuilt numerous times Program Details When a meter is exchanged the user retains his register and adapter as well as any other accessories he may have pr...

Страница 10: ...DIMENSIONS Measurements are in Inches...

Страница 11: ...Tokheim 682 meters there is a back pressure valve on the discharge of the meter which can become stuck shut 3 If it is determined that the problem i s in the meter itself then the meter valve inside...

Страница 12: ...METER ASSEMBLY 682 15...

Страница 13: ...r Shaft Seal Kit 1 227000 1 227000 1 227000 1 31 TCS Screw 7 16 14 X 1 1 4 10 3 230958 3 230958 1 130879 32 TCS Retaining Ring 0 320 ID X 0 025 T 1 12 053420 12 053420 33 TCS Bearing Retainer Plunger...

Страница 14: ...plunger cups 38 in piston 40 and carefully place into cylinders SEE PLUNGER CUP KIT for piston repair instructions DO NOT cut or crimp plunger cups D Main Pivot Wobble Plate Assembly 1 Screw the main...

Страница 15: ...to the meter drive shaft packing Install drive shaft packing Kit 9 SEE DRIVE SHAFT PACKING KIT INSTRUCTIONS for more information C Slide the counter drive gear assembly 15 with Rulon washer 14 over th...

Страница 16: ...meter body assembly and tighten down the screws Calibrate the meter according to instructions METER DRIVE SHAFT PACKING KIT INSTRUCTIONS 1 Remove screws that bolt the meter cover assembly to the mete...

Страница 17: ...ed NOTE Apply Loctite 271 or equivalent to the screw threads Be sure the cup is evenly spaced on the plunger disc and support 5 Form the cup by turning the plunger assembly in your hand using your thu...

Страница 18: ...AIR ELIMINATOR ASSEMBLY 640 15...

Страница 19: ...alve O Ring 1 64014 64014 19 Screw 10 64021 64021 640 AIR ELIMINATOR REPAIR INSTRUCTIONS 1 Remove the screws 19 that bolt the air eliminator base 11 to the cover assembly 1 2 Remove the screws 4 and w...

Страница 20: ...HYDRAULIC VALVE ASSEMBLY 650 15...

Страница 21: ...2 65035 65035 31 Plunger Cup Support 1 65014 65014 32 Plunger Cup 1 65013 65013 33 Plunger 1 65030 65030 34 Valve Disc 1 65009 65009 35 Valve Seat 1 65006 65006 36 Poppet Guide 1 65029 65029 37 Screw...

Страница 22: ...NOTES...

Страница 23: ...bligations under this warranty the original purchaser must obtain a Return Goods Authorization RGA number from TCS s customer service department within 30 days of discovery of a purported breach of wa...

Страница 24: ...682SM Rev 5 01 01 0 5 TOTAL CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com...

Отзывы: