682 METER BODY REPAIR INSTRUCTIONS 

 

 

I. 

A.  Remove all parts and seals from the meter body and clean them.  You may air blast parts with 

a glass bead material to clean parts. 

 

B.  Always replace bracket (#56), screws (#54) & (#34), plunger cups (#38) and Rulon seals 

(#14, 17 & 44). 

 

C.  Check for: 

1. 

Excessive wear on the wobble plate (#47) guide holes. 

2. 

Pitting on ball bearings (#49) & (#46). 

3. 

Excessive wear on the guide posts on main pivot bracket assembly (#53). 

4. 

Wear on the AF/SP valve (#57) or SS valve insert (#57). 

5. 

Wear on the valve seat (#58). 

6. 

Wrinkles on the sleeves in cylinders (TCS 1-126891) of the body.   
NOTE: Honing sleeves with Emory wheel may buff out wrinkles. 

 

II. 

A.  Mount valve seat (#58) to body (#60), with seat gasket (#59). 

 

B.  Lap valve (#57) for AF, SP or SS. 

1.  AF & SP – Use Rectorseal® Clover lapping compound or equivalent on 

valve (#57) & seat (#58).  Move valve repeatedly in a Figure 8, and clean 
compound off valve and seat thoroughly when finished. 

2.  SS – Use 220 & 320 grit silicon sand paper to lap valve & insert (#57).  

Move valve repeatedly in a Figure 8 on 220 grit paper, then use the 320 grit 
paper.  Wipe valve Rulon insert clean. 

 

C.  Replace plunger cups (#38) in piston (#40) and carefully place into cylinders.  

SEE PLUNGER CUP KIT for piston repair instructions.  

DO NOT cut or crimp plunger 

cups.

 

 

D.  Main Pivot & Wobble Plate Assembly. 

1.  Screw the main pivot assembly (#50) all the way into main pivot bracket 

assembly (#53) and place pinion (#51) in its slot.  For AF & SP meters, 
unscrew the pinion and main pivot bracket assembly 5 full turns.  For SS 
meters, unscrew the pinion and main pivot bracket assembly 3 ½ full turns.  
This should help bring meter within range while calibrating. 

2.  Drop the slotted screws (#54) into bracket. 
3.  Place bracket with screws into main pivot bracket assembly. 
4.  Set 5/8” ball bearing (#49) into position. 
5.  Place the wear plate (#48) over the screws (#54). 
6.  Set wobble plate (#47) onto the screws (#54) and fasten down with lock 

nuts (#41) & lock washers (#42). 

7.  Set slack spring assembly (#45) on wobble plate post with Rulon washer 

(#44) & slack roller (#43). 

8.  Mount main pivot bracket assembly to valve (#57) & seat (#58) with lock 

washers (#42) & screws (#52). 

 

E.  Connect Pistons to Wobble Plate. 

1.  Carefully slide connector (#36) over the wobble plate (#47) bearing seats.   
2.  Place 1/2” ball bearing (#46) onto wobble plate and cover with bearing seat 

(#35) & retainer (#33). 

3.  Rotate wobble plate (#47) & pistons (#40) through each cylinder to make 

sure of smooth flowing characteristics. 

Содержание 682-15

Страница 1: ...CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com The Standard of Measurement 682 15 Piston Flow Meter SERVICE...

Страница 2: ...s Alcohols Adhesives Motor Oils Molasses Corn Syrup Liquid Sugars Deicing Fluids etc SS Stainless Steel For metering all the same liquids as the SP and AF flow meters however includes special handling...

Страница 3: ...uct enters the meter it initially flows into the upper housing The sliding valve will now be in position to open one measuring cylinder The plunger for that particular cylinder will be at the upper po...

Страница 4: ...40 to 50 percent of flow Operating Temperature The temperature range of the product to be metered must be within the meter s range The SP meter can operate between 20 F and 200 F The AF and SS meters...

Страница 5: ...tire system Protection From Debris On new installations care must be taken to protect the meter from damage during start up Damage may result from the passage through the meter of welding slag or spat...

Страница 6: ...differ beyond the rated tolerance of the meter then repairs are necessary before the meter can be calibrated B A valve or nozzle must be at the end of the delivery hose at the prover C Turn on the pu...

Страница 7: ...0 5 10 15 20 0 5 10 15 20 25 30 35 40 GALLONS PER MINUTE P S I The 682 meter is mechanically capable of accurately metering products as slow as 0 2 GPM and as quick as 40 GPM Comparing the lowest and...

Страница 8: ...VISCOUS LIQUIDS PERFORMANCE...

Страница 9: ...epeat business for distributor 9 Meter can be rebuilt numerous times Program Details When a meter is exchanged the user retains his register and adapter as well as any other accessories he may have pr...

Страница 10: ...DIMENSIONS Measurements are in Inches...

Страница 11: ...Tokheim 682 meters there is a back pressure valve on the discharge of the meter which can become stuck shut 3 If it is determined that the problem i s in the meter itself then the meter valve inside...

Страница 12: ...METER ASSEMBLY 682 15...

Страница 13: ...r Shaft Seal Kit 1 227000 1 227000 1 227000 1 31 TCS Screw 7 16 14 X 1 1 4 10 3 230958 3 230958 1 130879 32 TCS Retaining Ring 0 320 ID X 0 025 T 1 12 053420 12 053420 33 TCS Bearing Retainer Plunger...

Страница 14: ...plunger cups 38 in piston 40 and carefully place into cylinders SEE PLUNGER CUP KIT for piston repair instructions DO NOT cut or crimp plunger cups D Main Pivot Wobble Plate Assembly 1 Screw the main...

Страница 15: ...to the meter drive shaft packing Install drive shaft packing Kit 9 SEE DRIVE SHAFT PACKING KIT INSTRUCTIONS for more information C Slide the counter drive gear assembly 15 with Rulon washer 14 over th...

Страница 16: ...meter body assembly and tighten down the screws Calibrate the meter according to instructions METER DRIVE SHAFT PACKING KIT INSTRUCTIONS 1 Remove screws that bolt the meter cover assembly to the mete...

Страница 17: ...ed NOTE Apply Loctite 271 or equivalent to the screw threads Be sure the cup is evenly spaced on the plunger disc and support 5 Form the cup by turning the plunger assembly in your hand using your thu...

Страница 18: ...AIR ELIMINATOR ASSEMBLY 640 15...

Страница 19: ...alve O Ring 1 64014 64014 19 Screw 10 64021 64021 640 AIR ELIMINATOR REPAIR INSTRUCTIONS 1 Remove the screws 19 that bolt the air eliminator base 11 to the cover assembly 1 2 Remove the screws 4 and w...

Страница 20: ...HYDRAULIC VALVE ASSEMBLY 650 15...

Страница 21: ...2 65035 65035 31 Plunger Cup Support 1 65014 65014 32 Plunger Cup 1 65013 65013 33 Plunger 1 65030 65030 34 Valve Disc 1 65009 65009 35 Valve Seat 1 65006 65006 36 Poppet Guide 1 65029 65029 37 Screw...

Страница 22: ...NOTES...

Страница 23: ...bligations under this warranty the original purchaser must obtain a Return Goods Authorization RGA number from TCS s customer service department within 30 days of discovery of a purported breach of wa...

Страница 24: ...682SM Rev 5 01 01 0 5 TOTAL CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com...

Отзывы: