682 METER EXCLUSIVE LIMITED WARRANTY 

 

 
 

WARRANTY

 

New 682 piston meters manufactured by Total Control Systems, a division of Murray Equipment, Inc. 
("TCS") with which this warranty is enclosed, are warranted by TCS to the original purchaser only for a 
period of ten (10) years from the date of shipment, to be free, under normal use and service, from defects in 
material and workmanship.  TCS manufactured new equipment or components are warranted for a period of 
one (1) year from the date of shipment, under normal use and service.  This warranty is extended only to the 
original purchaser.  For defects occurring within the stated warranty period, TCS will repair or replace, at 
TCS's option; provided that part or parts are returned to TCS transportation charges prepaid, and the TCS's 
examination discloses the parts or workmanship to have been defective upon delivery to the purchaser.   
 

EXCLUSIONS

 

TCS’s ten (10) year warranty applies to meters only and does not apply to accessories such as valves and 
air eliminators.  Parts and equipment not manufactured by TCS may be covered by separate warranties of 
their respective manufacturers.  This warranty does not cover any parts or equipment not manufactured by 
TCS or related companies.  This warranty does not extend to any equipment that has been altered in any way, 
subjected to misuse, negligence, accident, or if operated in any manner other than in accordance with TCS's 
operating instructions or have been operated under conditions more severe than, or otherwise exceeding those 
set forth in the specifications.  General maintenance, calibration, clean up and normal wear is excluded 
from this limited warranty.   
 

CLAIM PROCEDURES 

In order to obtain performance by TCS of its obligations under this warranty, the original purchaser must 
obtain a Return Goods Authorization (RGA) number from TCS’s customer service department within 30 
days of discovery of a purported breach of warranty, but not later than the expiration of the warranty 
period.  Once authorization is received, return the defective meter, piece of equipment, or component 
covered by this warranty, with transportation charges prepaid, to TCS at the address shown below together 
with a written statement setting forth the nature of the defect and RGA number. 

 
LIMITATIONS

 

THERE ARE NO OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED. TCS 
SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR 
ANY PARTICULAR PURPOSE. TCS will determine if all parts or meter defect falls within the warranty 
guidelines and will repair or replace within a reasonable time span.  TCS is not responsible for any in or 
out bound freight.  TCS's sole obligation that shall represent the buyer's sole and exclusive remedy shall be 
to repair or at TCS's option to replace any product or part determined to be defective. In no event shall TCS 
be liable for any special, direct, indirect, incident, consequential or other damages of similar nature, including 
without limitation, loss of profits, products, production time, or loss of expenses of any nature incurred by the 
buyer or any third party.  TCS has not authorized on its behalf any representation or warranties to be made, 
nor any liability to be assumed except as expressly provided herein; there is no other express or implied 
warranty. 
 

REPAIR WARRANTY 

All repair work is warranted for (90) days from the date of shipment to customer.  Some parts may be 
warranted for longer periods by the Original Equipment Manufacturer. 
 

DESIGN AND EQUIPMENT CHANGES 

Any changes in design or improvements added shall not create any obligation to install same on 
equipment previously sold or ordered. 
 

Содержание 682-15

Страница 1: ...CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com The Standard of Measurement 682 15 Piston Flow Meter SERVICE...

Страница 2: ...s Alcohols Adhesives Motor Oils Molasses Corn Syrup Liquid Sugars Deicing Fluids etc SS Stainless Steel For metering all the same liquids as the SP and AF flow meters however includes special handling...

Страница 3: ...uct enters the meter it initially flows into the upper housing The sliding valve will now be in position to open one measuring cylinder The plunger for that particular cylinder will be at the upper po...

Страница 4: ...40 to 50 percent of flow Operating Temperature The temperature range of the product to be metered must be within the meter s range The SP meter can operate between 20 F and 200 F The AF and SS meters...

Страница 5: ...tire system Protection From Debris On new installations care must be taken to protect the meter from damage during start up Damage may result from the passage through the meter of welding slag or spat...

Страница 6: ...differ beyond the rated tolerance of the meter then repairs are necessary before the meter can be calibrated B A valve or nozzle must be at the end of the delivery hose at the prover C Turn on the pu...

Страница 7: ...0 5 10 15 20 0 5 10 15 20 25 30 35 40 GALLONS PER MINUTE P S I The 682 meter is mechanically capable of accurately metering products as slow as 0 2 GPM and as quick as 40 GPM Comparing the lowest and...

Страница 8: ...VISCOUS LIQUIDS PERFORMANCE...

Страница 9: ...epeat business for distributor 9 Meter can be rebuilt numerous times Program Details When a meter is exchanged the user retains his register and adapter as well as any other accessories he may have pr...

Страница 10: ...DIMENSIONS Measurements are in Inches...

Страница 11: ...Tokheim 682 meters there is a back pressure valve on the discharge of the meter which can become stuck shut 3 If it is determined that the problem i s in the meter itself then the meter valve inside...

Страница 12: ...METER ASSEMBLY 682 15...

Страница 13: ...r Shaft Seal Kit 1 227000 1 227000 1 227000 1 31 TCS Screw 7 16 14 X 1 1 4 10 3 230958 3 230958 1 130879 32 TCS Retaining Ring 0 320 ID X 0 025 T 1 12 053420 12 053420 33 TCS Bearing Retainer Plunger...

Страница 14: ...plunger cups 38 in piston 40 and carefully place into cylinders SEE PLUNGER CUP KIT for piston repair instructions DO NOT cut or crimp plunger cups D Main Pivot Wobble Plate Assembly 1 Screw the main...

Страница 15: ...to the meter drive shaft packing Install drive shaft packing Kit 9 SEE DRIVE SHAFT PACKING KIT INSTRUCTIONS for more information C Slide the counter drive gear assembly 15 with Rulon washer 14 over th...

Страница 16: ...meter body assembly and tighten down the screws Calibrate the meter according to instructions METER DRIVE SHAFT PACKING KIT INSTRUCTIONS 1 Remove screws that bolt the meter cover assembly to the mete...

Страница 17: ...ed NOTE Apply Loctite 271 or equivalent to the screw threads Be sure the cup is evenly spaced on the plunger disc and support 5 Form the cup by turning the plunger assembly in your hand using your thu...

Страница 18: ...AIR ELIMINATOR ASSEMBLY 640 15...

Страница 19: ...alve O Ring 1 64014 64014 19 Screw 10 64021 64021 640 AIR ELIMINATOR REPAIR INSTRUCTIONS 1 Remove the screws 19 that bolt the air eliminator base 11 to the cover assembly 1 2 Remove the screws 4 and w...

Страница 20: ...HYDRAULIC VALVE ASSEMBLY 650 15...

Страница 21: ...2 65035 65035 31 Plunger Cup Support 1 65014 65014 32 Plunger Cup 1 65013 65013 33 Plunger 1 65030 65030 34 Valve Disc 1 65009 65009 35 Valve Seat 1 65006 65006 36 Poppet Guide 1 65029 65029 37 Screw...

Страница 22: ...NOTES...

Страница 23: ...bligations under this warranty the original purchaser must obtain a Return Goods Authorization RGA number from TCS s customer service department within 30 days of discovery of a purported breach of wa...

Страница 24: ...682SM Rev 5 01 01 0 5 TOTAL CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com...

Отзывы: