COMPENSATOR SHAFT SEAL KIT INSTRUCTIONS 

 

 

1)  Remove screws that bolt the meter cover assembly to the 

meter body.  Loosen and remove the entire  meter cover 
assembly. 

2)  Cut seal wire and remove seal pin from index disc. 
3)  Unscrew hex nut from the compensator shaft.  Remove 

compensator washer, index disc, index plate and 
compression spring from the shaft. 

4)  From inside the cover housing, turn the compensator shaft 

until the attached truarc "E" retaining ring or cotter pin clears 
the edge of the counter drive gear.  Slide the compensator 
shaft assembly from the housing. 

5)  Remove the spacer.  Lift the old packing from the housing.  

Be sure there are no foreign particles left in the cavity. 

6)  Replace the compensator shaft assembly into the cover 

housing.  Support the shaft from beneath while packing the 
new seal and spacer. 

7)  SEE ILLUSTRATION FOR PACKING SEQUENCE 
8)  Replace the compression spring, index plate, index disc, 

compensator washer and hex nut to the compensator shaft.  Do not fully tighten the hex nut until the meter has 
been calibrated. 

9)  Reassemble the meter cover assembly to the meter body assembly and tighten down the screws. Calibrate the 

meter according to instructions. 

 
 

METER DRIVE SHAFT PACKING KIT INSTRUCTIONS 

 

1) 

Remove screws that bolt the meter cover assembly to the 
meter body.  Loosen and remove the entire meter cover 
assembly. 

2) 

Carefully remove the roll pin from the drive shaft. 

3) 

Remove (3) screws, (3) lock washers, and the 
compression washer. 

4) 

From inside the cover housing, remove the retaining ring 
or cotter pin from the counter drive shaft.  Remove the 
counter drive gear and washers.  Slide the drive shaft 
assembly from the housing. 

5) 

Lift the old packing from the housing.  Be sure there are 
no foreign particles left in the cavity. 

6) 

Replace the drive shaft assembly into the cover housing.  
Secure in position by reassembling the counter drive gear 
with the washers and retaining ring or cotter pin 
previously removed. 

7) 

Support the counter drive shaft assembly from beneath 
while packing the spacer bearings, washers and the new 
seal. 

8) 

SEE ILLUSTRATION FOR PACKING SEQUENCE 

9) 

Replace the compression washer with the screws and lock washers. 

10)  Insert the roll pin in the drive shaft.  Be sure to support the shaft while doing this to prevent bending it. 
11)  Reassemble the meter cover assembly to the meter body assembly and tighten down the screws. 

 

Содержание 682-15

Страница 1: ...CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com The Standard of Measurement 682 15 Piston Flow Meter SERVICE...

Страница 2: ...s Alcohols Adhesives Motor Oils Molasses Corn Syrup Liquid Sugars Deicing Fluids etc SS Stainless Steel For metering all the same liquids as the SP and AF flow meters however includes special handling...

Страница 3: ...uct enters the meter it initially flows into the upper housing The sliding valve will now be in position to open one measuring cylinder The plunger for that particular cylinder will be at the upper po...

Страница 4: ...40 to 50 percent of flow Operating Temperature The temperature range of the product to be metered must be within the meter s range The SP meter can operate between 20 F and 200 F The AF and SS meters...

Страница 5: ...tire system Protection From Debris On new installations care must be taken to protect the meter from damage during start up Damage may result from the passage through the meter of welding slag or spat...

Страница 6: ...differ beyond the rated tolerance of the meter then repairs are necessary before the meter can be calibrated B A valve or nozzle must be at the end of the delivery hose at the prover C Turn on the pu...

Страница 7: ...0 5 10 15 20 0 5 10 15 20 25 30 35 40 GALLONS PER MINUTE P S I The 682 meter is mechanically capable of accurately metering products as slow as 0 2 GPM and as quick as 40 GPM Comparing the lowest and...

Страница 8: ...VISCOUS LIQUIDS PERFORMANCE...

Страница 9: ...epeat business for distributor 9 Meter can be rebuilt numerous times Program Details When a meter is exchanged the user retains his register and adapter as well as any other accessories he may have pr...

Страница 10: ...DIMENSIONS Measurements are in Inches...

Страница 11: ...Tokheim 682 meters there is a back pressure valve on the discharge of the meter which can become stuck shut 3 If it is determined that the problem i s in the meter itself then the meter valve inside...

Страница 12: ...METER ASSEMBLY 682 15...

Страница 13: ...r Shaft Seal Kit 1 227000 1 227000 1 227000 1 31 TCS Screw 7 16 14 X 1 1 4 10 3 230958 3 230958 1 130879 32 TCS Retaining Ring 0 320 ID X 0 025 T 1 12 053420 12 053420 33 TCS Bearing Retainer Plunger...

Страница 14: ...plunger cups 38 in piston 40 and carefully place into cylinders SEE PLUNGER CUP KIT for piston repair instructions DO NOT cut or crimp plunger cups D Main Pivot Wobble Plate Assembly 1 Screw the main...

Страница 15: ...to the meter drive shaft packing Install drive shaft packing Kit 9 SEE DRIVE SHAFT PACKING KIT INSTRUCTIONS for more information C Slide the counter drive gear assembly 15 with Rulon washer 14 over th...

Страница 16: ...meter body assembly and tighten down the screws Calibrate the meter according to instructions METER DRIVE SHAFT PACKING KIT INSTRUCTIONS 1 Remove screws that bolt the meter cover assembly to the mete...

Страница 17: ...ed NOTE Apply Loctite 271 or equivalent to the screw threads Be sure the cup is evenly spaced on the plunger disc and support 5 Form the cup by turning the plunger assembly in your hand using your thu...

Страница 18: ...AIR ELIMINATOR ASSEMBLY 640 15...

Страница 19: ...alve O Ring 1 64014 64014 19 Screw 10 64021 64021 640 AIR ELIMINATOR REPAIR INSTRUCTIONS 1 Remove the screws 19 that bolt the air eliminator base 11 to the cover assembly 1 2 Remove the screws 4 and w...

Страница 20: ...HYDRAULIC VALVE ASSEMBLY 650 15...

Страница 21: ...2 65035 65035 31 Plunger Cup Support 1 65014 65014 32 Plunger Cup 1 65013 65013 33 Plunger 1 65030 65030 34 Valve Disc 1 65009 65009 35 Valve Seat 1 65006 65006 36 Poppet Guide 1 65029 65029 37 Screw...

Страница 22: ...NOTES...

Страница 23: ...bligations under this warranty the original purchaser must obtain a Return Goods Authorization RGA number from TCS s customer service department within 30 days of discovery of a purported breach of wa...

Страница 24: ...682SM Rev 5 01 01 0 5 TOTAL CONTROL SYSTEMS 2515 Charleston Place Fort Wayne IN 46808 800 348 4753 260 484 0382 Fax 260 484 9230 sales tcsmeters com www tcsmeters com...

Отзывы: