36
15
The frequency after the frequency limit
16
The frequency sending to compressor control
chip
17
Indoor unit A evaporator outlet temperature (T
2B
A)
If the temperature is lower than -9
℃
, the digital display shows “-9.
”
If the
temperature is higher than 70
℃
, the digital display shows “70.
”
If the
indoor unit is not connected, the digital display shows
: “――”
18
Indoor unit B evaporator outlet temperature (T
2B
B)
19
Indoor unit C evaporator outlet temperature
(T
2B
C)
20
Indoor unit D evaporator outlet temperature
(T
2B
D)
21
Indoor unit E evaporator outlet temperature (T
2B
E)
22
Indoor unit A room temperature (T
1
A)
If the temperature is lower than 0
℃
, the digital display shows “0.
”
If the
temperature is higher than 50
℃
, the digital display shows “50.
” If the
indoor unit is not connected, the digital display shows
: “――”
23
Indoor unit B room temperature (T
1
B)
24
Indoor unit C room temperature (T
1
C)
25
Indoor unit D room temperature (T
1
D)
26
Indoor unit E room temperature (T
1
E)
27
Indoor unit A evaporator temperature (T
2
A)
If the temperature is lower than -9
℃
, the digital display shows “-9.
”
If the
temperature is higher than 70
℃
, the digital display shows “70.
” If the
indoor unit is not connected, the digital display shows
: “――”
28
Indoor unit B evaporator temperature (T
2
B)
29
Indoor unit C evaporator temperature (T
2
C)
30
Indoor unit D evaporator temperature (T
2
D)
31
Indoor unit E evaporator temperature (T
2
E)
32
Condenser pipe temperature (T3)
33
Outdoor ambient temperature (T4)
34
Compressor discharge temperature (TP)
The display value is between 30–129
℃
. If the temperature is lower than
30
℃
, the digital display shows “30.
”
If the temperature is higher than 99
℃
, the digital display shows single and double digits. For example, if the
digital display shows “0.5", the compressor discharge temperature is 105
℃
.
35
AD value of current
The display value is a hex number.
For example, the digital display tube shows “Cd
”
, it means AD value is
205.
36
AD value of voltage
37
EXV open angle for A indoor unit
Actual data/4.
If the value is higher than 99, the digital display shows single and double
digits.
For example, if the digital display shows “2.0", the EXV open angle is
120×4=480p.
38
EXV open angle for B indoor unit
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
Bit7
Frequency limit caused by IGBT
radiator
The display value
is a hexidecimal
number. For
example, the
digital display
show 2A, then
Bit5=1, Bit3=1,
and Bit1=1.
This means that
a frequency limit
may be caused
by T4, T3, or the
current.
Bit6
Frequency limit caused by PFC
Bit5
Frequency limit caused by T4.
Bit4
Frequency limit caused by T2.
Bit3
Frequency limit caused by T3.
Bit2
Frequency limit caused by T5.
Bit1
Frequency limit caused by current
Bit0
Frequency limit caused by voltage
43
Average value of T2
(Sum T2 value of all indoor units)/(number of indoor units in good
connection)
44
Outdoor unit fan motor state
Off: 0, High speed:1, Med speed: 2, Low speed: 3, Breeze:4, Super
breeze: 5
45
The last error or protection code
00 means no malfunction and protection
46
F indoor unit capacity
47
F indoor unit capacity demand code
48
F indoor unit evaporator outlet temperature (T
2B
F)
Содержание MMCUT18AS2
Страница 3: ...3 MMCUT36AS4 WD30 metal plate 114 MMCUT48AS5 WE30 metal plate 121...
Страница 10: ...10...
Страница 23: ...23 6 Wiring Diagrams 6 1 Wiring diagram of 1 drive 2 outdoor MMCUT18AS2...
Страница 24: ...24 6 2 Wiring diagram of 1 drive 3 outdoor MMCUT27AS3...
Страница 25: ...25 6 3 Wiring diagram of 1 drive 4 outdoor MMCUT36AS4...
Страница 29: ...29...
Страница 43: ...43 Operating Standby Pic 2 IPM for 2 zone 3 zone...
Страница 44: ...44 PIC3 Main board LED when power on and unit standby Pic 2 IPM for5 zone Power Standby Operating...
Страница 59: ...59 Operating Standby Pic 2 IPM board for 2 zone 3 zone...
Страница 60: ...60 PIC3 Main board LED when power on and unit standby Pic 2 IPM for5 zone Power Standby Operating...
Страница 66: ...66 IPM board for 2 zone 3 zone...
Страница 68: ...68 IPM board for 4 zone...
Страница 71: ...71 Two ports of the inductance Inductance...
Страница 74: ...74 Vs Vcc Vsp FG...
Страница 77: ...77...
Страница 80: ...80...
Страница 83: ...83...
Страница 94: ...94 6 EXV check Disconnect the connectors...
Страница 95: ...95 Resistance to EXV coil Color of lead wire Normal Value Red Blue About 50 Red Yellow Brown Orange Brown White...
Страница 96: ...96 Red Blue Red Yellow...
Страница 97: ...97 Brown Orange...
Страница 98: ...98 Brown White...
Страница 108: ...108 Screws of right rear panel Screws of terminal board...